Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.767
Filtrar
1.
Int. j. morphol ; 42(4): 1053-1061, ago. 2024. tab
Artigo em Inglês | LILACS | ID: biblio-1569267

RESUMO

SUMMARY: Military readiness relies heavily on the physical fitness and operational capability of its personnel. This study aims to enhance the effectiveness of body composition assessment and classification protocols within the military context. A comprehensive evaluation of 4370 active-duty Chilean military personnel was conducted, focusing on anthropometric characteristics, including adipose tissue, muscle tissue, and anthropometric indices. The study observed significant differences in body composition between genders, with men exhibiting lower levels of body fat percentage (men: 26.28 %; women: 34.62 %) but higher levels of muscle mass (men: 42.0 %; women: 36.0 %;), skeletal muscle index (men:11.81; women: 9.31), and fat-free mass index (men: 19.92; women: 18.45) compared to women. High levels of muscle tissue were observed in both groups. By integrating these findings into a standardized assessment protocol, a more accurate classification of military personnel was achieved, surpassing traditional methods used in sedentary obese populations. The study advocates the future adoption of an assessment model based on artificial intelligence (AI) algorithms, which consider the multifaceted nature of body composition and its impact on operational capability. Such a model would enable military forces to optimize their personnel's physical fitness and readiness, thus enhancing their effectiveness in deployment operations.


La preparación militar depende en gran medida de la aptitud física y la capacidad operativa de su personal. Este estudio tiene como objetivo mejorar la eficacia de los protocolos de evaluación y clasificación de la composición corporal dentro del contexto militar. Se realizó una evaluación integral de 4.370 militares chilenos en servicio activo, centrándose en las características antropométricas, incluido el tejido adiposo, el tejido muscular y los índices antropométricos. El estudio observó diferencias significativas en la composición corporal entre sexos, con los hombres exhibiendo niveles más bajos de porcentaje de grasa corporal (hombres: 26,28 %; mujeres: 34,62 %) pero niveles más altos de masa muscular (hombres: 42,0 %; mujeres: 36,0 %;), índice de músculo esquelético (hombres: 11,81; mujeres: 9,31) e índice de masa magra (hombres: 19,92; mujeres: 18,45) en comparación con las mujeres. Se observaron altos niveles de tejido muscular en ambos grupos. Al integrar estos hallazgos en un protocolo de evaluación estandarizado, se logró una clasificación más precisa del personal militar, superando los métodos tradicionales utilizados en poblaciones obesas sedentarias. El estudio aboga por la adopción futura de un modelo de evaluación basado en algoritmos de inteligencia artificial (IA), que consideren la naturaleza multifacética de la composición corporal y su impacto en la capacidad operativa. Un modelo de este tipo permitiría a las fuerzas militares optimizar la aptitud física y la preparación de su personal, mejorando así su eficacia en las operaciones de despliegue.


Assuntos
Humanos , Masculino , Feminino , Adulto , Adulto Jovem , Composição Corporal , Caracteres Sexuais , Militares , Fatores Sexuais , Antropometria , Impedância Elétrica
2.
Cien Saude Colet ; 29(8): e05762023, 2024 Aug.
Artigo em Português | MEDLINE | ID: mdl-39140541

RESUMO

This paper involves the analysis of the quality of anthropometric data on children under five years of age in two information systems in the State of São Paulo. The sample included 2,117,108 children from the Food and Nutrition Surveillance System (SISVAN), and 748,551 from the State Milk Project (VIVALEITE). Initially, we evaluated the frequency of missing values and others outside the equipment spectrum and calculated the digit-to-weight preference index. After calculating height-for-age (HAZ), weight-for-age (WAZ), and body mass index-for-age (BAZ), we flagged the biologically implausible values (BIV) and calculated the standard deviation (SD). For each municipality, we calculated the mean and the SD of HAZ, WAZ, and BAZ; and plotted the SD values as a function of the mean. The digit-to-weight preference index was greater among children aged between 24 and 59 months in SISVAN. The frequency of BIV for HAZ (SISVAN 2.56%; VIVALEITE 0.98%) was higher than for WAZ (SISVAN 2.10%; VIVALEITE 0.18%). For HAZ, variations among municipalities were more pronounced in VIVALEITE than in SISVAN. The height variable presents low reliability in both systems. The weight variable reveals satisfactory quality in VIVALEITE and unsatisfactory quality in SISVAN.


O objetivo foi analisar a qualidade dos dados antropométricos de crianças menores de cinco anos em dois sistemas de informação no estado de São Paulo. A amostra compreendeu 2.117.108 crianças do Sistema de Vigilância Alimentar e Nutricional (Sisvan) e 748.551 do Projeto Estadual do Leite (Vivaleite). Inicialmente, avaliamos a frequência de valores faltantes e fora do espectro do equipamento, e calculamos o índice de preferência de dígito para peso. Após calcular os índices de altura para idade (A-I), peso para idade (P-I) e índice de massa corporal para idade (IMC-I), identificamos os valores biologicamente implausíveis (VBI) e calculamos o desvio-padrão (DP). Para cada município, calculamos a média e o DP de A-I, P-I e IMC-I; e plotamos os valores de DP em função da média. A preferência de dígito no peso foi maior em crianças de 24 a 59 meses no Sisvan. A frequência de VBI para A-I (SISVAN 2,56%; Vivaleite 0,98%) foi maior do que para P-I (Sisvan 2,10%; Vivaleite 0,18%). Para o índice A-I as variações entre os municípios foram mais acentuadas no Vivaleite do que no Sisvan. A variável altura apresentou baixa confiabilidade nos dois sistemas. A variável peso apresentou qualidade satisfatória no Vivaleite e insatisfatória no Sisvan.


Assuntos
Antropometria , Estatura , Peso Corporal , Sistemas de Informação , Brasil , Humanos , Lactente , Pré-Escolar , Feminino , Masculino , Sistemas de Informação/normas , Índice de Massa Corporal , Confiabilidade dos Dados , Fatores Etários
4.
Artigo em Inglês | MEDLINE | ID: mdl-39063471

RESUMO

This study aimed to investigate the resting metabolic rate (RMR) in cross-training practitioners (advanced and novice) using indirect calorimetry (IC) and compare it with predictive equations proposed in the scientific literature. METHODS: A cross-sectional and comparative study analyzed 65 volunteers, both sexes, practicing cross-training (CT). Anthropometry and body composition were assessed, and RMR was measured by IC (FitMate PRO®), bioimpedance (BIA-InBody 570®), and six predictive equations. Data normality was tested by the Kolgomorov-Smirnov test and expressed as mean ± standard deviation with 95% confidence intervals (CI), chi-square test was performed to verify ergogenic resources, and a Bland-Altman plot (B&A) was made to quantify the agreement between two quantitative measurements. One-way ANOVA was applied to body composition parameters, two-way ANOVA with Bonferroni post hoc was used to compare the RMR between groups, and two-way ANCOVA was used to analyze the adjusted RMR for body and skeletal muscle mass. The effect size was determined using Cohen's d considering the values adjusted by ANCOVA. If a statistical difference was found, post hoc Bonferroni was applied. The significance level was p < 0.05 for all tests. RESULTS: The main results indicated that men showed a higher RMR than women, and the most discrepant equations were Cunningham, Tinsley (b), and Johnstone compared to IC. Tinsley's (a) equation indicated greater precision in measuring the RMR in CM overestimated it by only 1.9%, and BIA and the Harris-Benedict in CW overestimated RMR by only 0.1% and 3.4%, respectively. CONCLUSIONS: The BIA and Harris-Benedict equation could be used reliably to measure the RMR of females, while Tinsley (a) is the most reliable method to measure the RMR of males when measuring with IC is unavailable. By knowing which RMR equations are closest to the gold standard, these professionals can prescribe a more assertive diet, training, or ergogenic resources. An assertive prescription increases performance and can reduce possible deleterious effects, maximizing physical sports performance.


Assuntos
Metabolismo Basal , Composição Corporal , Calorimetria Indireta , Humanos , Masculino , Feminino , Estudos Transversais , Adulto , Adulto Jovem , Antropometria , Impedância Elétrica
5.
PLoS One ; 19(7): e0305410, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38985776

RESUMO

Anthropometric studies of the scapula have been rare in Spanish populations, nevertheless they are of current interest in forensic anthropology for estimation of sex. Although the estimation of sex is usually carried out on the pelvis and skull, other measurements related to the scapula can be helpful when the skeletal remains are incomplete. Glenohumeral osteoarthritis development is influenced, among others, by the morphology of the scapula, which is one of the less studied aspects. We carried out a descriptive study of anthropometric parameters in a series of 157 scapulae (82 individuals) on bone remains dated to the 20th century from a population of Granada (Southern Spain). Seventy seven (49%) were right-side and 80 (51%) left-side; 72 (45.9%) were from males and 85 (54.1%) from females, and the mean age at death was 70.76±11.7 years. The objective was to develop a discrimination function for sex estimation based on anthropometric parameters of the scapula other than those considered to date, and to analyze the prevalence of glenohumeral osteoarthritis in relation to selected anthropometric parameters. A logistic regression model based on parameters of the upper-external segment of the scapula was done. The obtained formula: 1/1+e^ (- (-57.911 + 0.350*B + 0283*C + 0.249*b + 0.166*a +-0.100*ß) classifies male sex with 98.3% accuracy and female sex with 92.1%. Glenohumeral osteoarthritis was detected in 16.6% of individuals and was related to age (p<0.05), scapular length (p<0.05), glenoid width (p<0.05), glenopolar angle (p<0.05), and α angle (p<0.05) in bivariate analyses but showed no significant associations in multivariate analyses. This approach can be useful for anthropological-forensic identification when scapula remains are incomplete. Glenohumeral osteoarthritis is significantly associated with a smaller α angle.


Assuntos
Antropometria , Osteoartrite , Escápula , Humanos , Masculino , Feminino , Osteoartrite/epidemiologia , Osteoartrite/patologia , Escápula/patologia , Escápula/anatomia & histologia , Espanha/epidemiologia , Idoso , Pessoa de Meia-Idade , Prevalência , Antropometria/métodos , Idoso de 80 Anos ou mais , Articulação do Ombro/patologia , Articulação do Ombro/anatomia & histologia , Determinação do Sexo pelo Esqueleto/métodos
6.
Rev Assoc Med Bras (1992) ; 70(6): e20231571, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39045954

RESUMO

OBJECTIVE: The aim of this study was to characterize the anthropometric, lipid, and dietary profiles of postmenopausal women with metabolic syndrome attending a public health service and compare them with a group of women without metabolic syndrome. METHODS: A cross-sectional study was conducted with 60 postmenopausal women who were divided into two groups: control group and metabolic syndrome group, attending the Climacteric Outpatient Clinic at Santa Casa de São Paulo Hospital, Brazil, between February 2019 and December 2021. Participants were evaluated using a validated semi-quantitative food frequency questionnaire, body mass index, waist circumference, and serum laboratory tests. RESULTS: Significant differences were observed between the groups regarding body mass index and all parameters of metabolic syndrome. The nutritional profile revealed an imbalance in the number of food portions consumed, particularly in the intake of carbohydrates in the form of flour and sweets, which was higher in the metabolic syndrome group. CONCLUSION: The analysis of the three profiles of postmenopausal women revealed significant imbalances, particularly in the metabolic syndrome group, highlighting the importance of regular adjustments and evaluations during this phase of a woman's life.


Assuntos
Índice de Massa Corporal , Síndrome Metabólica , Circunferência da Cintura , Humanos , Feminino , Síndrome Metabólica/sangue , Estudos Transversais , Pessoa de Meia-Idade , Brasil/epidemiologia , Pós-Menopausa/fisiologia , Pós-Menopausa/sangue , Lipídeos/sangue , Menopausa/fisiologia , Menopausa/sangue , Dieta , Estudos de Casos e Controles , Comportamento Alimentar/fisiologia , Idoso , Antropometria
7.
Rev Assoc Med Bras (1992) ; 70(6): e20240049, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39045963

RESUMO

OBJECTIVE: The objective of this study was to estimate the accuracy of measuring neck circumference as a diagnostic method for overweight in 10-year-old children. METHODS: A cross-sectional diagnostic accuracy study was performed in 2019. The population was composed of 942 school children from the municipality of Palhoça, SC, Brazil. For each measurement of the neck circumference, sensitivity, specificity, positive and negative predictive values, likelihood ratio for a positive test, and accuracy were estimated using the receiver operator characteristic curve, with body mass index as a reference. RESULTS: The estimated overall accuracy was 88.9%. For males, the accuracy was 90.1%, and for females, 88.5%. A 30.0 cm neck circumference had a sensitivity of 22.8%, a specificity of 95.4%, a positive predictive value of 76.6%, a negative predictive value of 65.3%, a likelihood ratio for a positive test of 5.0, and an accuracy of 66.7% for all students. CONCLUSION: Neck circumference showed a global accuracy of 88.9% as a method for diagnosing overweight in 10-year-old children. Predictive values showed high values, mainly starting with a neck circumference of 30 cm.


Assuntos
Índice de Massa Corporal , Pescoço , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Humanos , Criança , Masculino , Feminino , Estudos Transversais , Pescoço/anatomia & histologia , Brasil , Reprodutibilidade dos Testes , Obesidade Infantil/diagnóstico , Curva ROC , Valores de Referência , Sobrepeso/diagnóstico , Antropometria/métodos
8.
Int. j. morphol ; 42(3): 561-566, jun. 2024. tab
Artigo em Inglês | LILACS | ID: biblio-1564618

RESUMO

SUMMARY: This study aims to investigate body typologies based on a combination of basic anthropo-morphological characteristics and body composition measured by multichannel bioimpedance in a sample from the adult population of Lebanon. A total of 302 subjects (173 males and 129 females) without acute or chronic health disorders were included in the study. Body composition was measured by the multichannel bioelectrical impedance (BIA) method, using the i30 device (MEDIANA, Korea). The research used 10 variables, including three basic anthropo-morphological variables, three for assessing fat, three for assessing the muscle component, and one index variable. K-means cluster analysis was used to define five specific clusters (5D) of body types based on sex. In light of the results, the study established five distinct clusters representing five different body typologies among Lebanese adults, categorized by sex: Male sample, Group 1 - Obese Endomorph (15.61 %), Group 2 - Balanced Mesomorph (16.76 %), Group 3 - Short Endomorph (30.06 %), Group 4 - Short Mesomorph (34.10 %), and Group 5 - Pathological Obese Endomorph (3.47 %); Female sample, Group 1- Obese Endomorph (2.33 %), Group 2 - Short Endo/Mesomorph (28.68 %), Group 3 - Short Ectomorph (32.56 %), Group 4 - Endomorph (22.48 %), and Group 5 - Balanced Mesomorph (13.95 %). Furthermore, the results indicated that the primary factor contributing to the distinctions among the identified clusters in terms of sex is fat tissue. This leads to the conclusion that eating habits cause the given differences, rather than the level of physical activity, regardless of sex.


Este estudio ttuvo como objetivo investigar tipologías corporales basadas en una combinación de características antropomorfológicas básicas y composición corporal, medidas por bioimpedancia multicanal, en una muestra de la población adulta del Líbano. Se incluyeron en el estudio un total de 302 sujetos (173 hombres y 129 mujeres) sin trastornos de salud agudos o crónicos. La composición corporal se midió mediante el método de impedancia bioeléctrica multicanal (BIA), utilizando el dispositivo i30 (MEDIANA, Corea). La investigación utilizó 10 variables, incluidas tres variables antropomorfológicas básicas, tres para evaluar la grasa, tres para evaluar el componente muscular y una variable índice. Se utilizó el análisis de conglomerados de K-medias para definir cinco conglomerados específicos (5D) de tipos de cuerpo según el sexo. En base a los resultados, el estudio estableció cinco grupos distintos que representan cinco tipologías corporales diferentes entre los adultos libaneses, categorizados por sexo: muestra masculina, grupo 1: endomorfo obeso (15,61 %), grupo 2: mesomorfo equilibrado (16,76 %), grupo 3 - Endomorfo Corto (30,06 %), Grupo 4 - Mesomorfo Corto (34,10 %), y Grupo 5 - Endomorfo Obeso Patológico (3,47 %); Muestra femenina, Grupo 1: Endomorfo obeso (2,33 %), Grupo 2: Endo/mesomorfo corto (28,68 %), Grupo 3: Ectomorfo corto (32,56 %), Grupo 4: Endomorfo (22,48 %) y Grupo 5: Mesomorfo equilibrado (13,95 %). Además, los resultados indicaron que el factor principal que contribuye a las distinciones entre los grupos identificados en términos de sexo es el tejido adiposo. Esto lleva a la conclusión de que las diferencias dadas son causadas por los hábitos alimentarios, más que por el nivel de actividad física, independientemente del sexo.


Assuntos
Humanos , Masculino , Feminino , Somatotipos , Composição Corporal , Antropometria , Tecido Adiposo , Análise de Variância , Impedância Elétrica , Líbano
9.
Nutrition ; 125: 112484, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38905911

RESUMO

OBJECTIVES: This study aimed to develop and cross-validate a fat-free mass (FFM) predictive equation using multifrequency bioelectrical impedance analysis (BIA) data in adolescent soccer athletes. METHODS: Male adolescent soccer athletes (n = 149; 13-19 y old) were randomly sorted using Excel and independently selected for development group (n = 100) or cross-validation group (n = 49). The FFM reference values were determined using dual-energy X-ray absorptiometry. Single-frequency BIA was used to plot tolerance ellipses. Multifrequency-BIA raw data were used as independent variables in regression models. Student's independent t-test was used to compare development and cross-validation groups. Stepwise multiple regression was used to develop the FFM predictive equation. Bland-Altman plots, Lin's concordance correlation coefficient, according to McBride criteria, precision, accuracy, and standard error of estimate (SEE) were calculated to evaluate the concordance and reliability of estimates. Bioelectrical impedance vector analysis was plotted to assess hydration status. RESULTS: No differences (P > 0.05) were observed between development and validation groups in chronological age, anthropometric data, bioelectrical impedance data, and FFM values obtained using dual-energy X-ray absorptiometry. Bioelectrical impedance vector analysis tolerance showed that all participants presented adequate hydration status compared to the reference population. The new FFM predictive equation developed and validated: FFM (kg) = -7.064 + 0.592 × chronological age (y) + 0.554 × weight (kg) + 0.365 × height²/resistance (cm²/Ω), presented R² = 0.95; SEE = 1.76 kg; concordance correlation coefficient = 0.95, accuracy = 0.98, and strength of concordance = 0.99. CONCLUSIONS: The present study developed and cross-validated an FFM predictive equation based on multifrequency bioelectrical data providing substantial FFM accuracy for male adolescent soccer athletes.


Assuntos
Absorciometria de Fóton , Atletas , Composição Corporal , Impedância Elétrica , Futebol , Humanos , Adolescente , Futebol/fisiologia , Masculino , Composição Corporal/fisiologia , Absorciometria de Fóton/métodos , Atletas/estatística & dados numéricos , Reprodutibilidade dos Testes , Adulto Jovem , Valores de Referência , Antropometria/métodos , Índice de Massa Corporal
10.
J Sports Sci ; 42(8): 737-750, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38836573

RESUMO

The aims of the present study were to: i) analyse the between-session reliability of dry-land and in-water swimming tests, and ii) investigate the prevalence of meaningful asymmetries in swimming athletes. Twenty-eight swimmers (21 males, 7 females) performed anthropometric, shoulder range of motion (ROM), countermovement jump, shoulder isokinetic torque, and 15-s tethered swimming tests two times, 1 week apart. Inter-limb asymmetries were calculated for each variable. Raw data reliability was determined using the intraclass coefficient correlation (ICC) and the typical error of measurement (TEM), and effect size (ES) was used to determine systematic bias between test sessions. At an individual level, inter-limb asymmetries were compared to the coefficient of variation (CV) to determine whether they were real. The between-session reliability was good to excellent (0.75 to 1.00) for most of the raw data, except for ROM. Between-session ES was predominately "trivial" or "small" for raw data and asymmetries, reinforcing that the values did not change significantly between the sessions. In addition, real asymmetries were seen in some tested metrics, depending on the test. In conclusion, the tested variables presented good levels of between-session reliability and were able to detect real and consistent asymmetries.


Assuntos
Teste de Esforço , Amplitude de Movimento Articular , Natação , Humanos , Natação/fisiologia , Masculino , Reprodutibilidade dos Testes , Feminino , Adolescente , Amplitude de Movimento Articular/fisiologia , Teste de Esforço/métodos , Adulto Jovem , Torque , Antropometria , Ombro/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA