Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Foot Ankle Spec ; 16(3): 226-232, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35656840

RESUMO

INTRODUCTION: The promising data from Ankle Arthroplasty are consequence of the evolution of instruments and implants. Recent studies have shown good results in the short and intermediate follow-up, in addition to high patient satisfaction. The aim of this study is to present the results obtained with 49 cases treated with the Infinity total ankle prosthesis in 2 South America countries. METHODS: This is a case series of 48 patients (27 women and 22 men), treated with 49 Infinity prostheses in Brazil and Colombia. They underwent surgical treatment between April 1, 2016, and January 18, 2020. We used the visual-analogue pain scale (VAS), the AOFAS score for ankle and hindfoot and the measurement of range of motion (ROM) in the pre- and post-surgical period. The radiological evaluation was performed on ankle radiographs in anteroposterior and lateral views, obtained in orthostasis, measuring the parameters suggested by Hintermann. Average follow-up was 4 years. RESULTS: VAS reduced from an average of 7.94 to 1.98; AOFAS increased from 28.02 to 83.16 and ROM increased from 11.45 to 28.08. Distal Tibial Slope is higher for higher improvements in VAS and lower for higher improvements in AOFAS and ROM. We observed 4 wound infections, 1 intra-op medial malleolus fracture. No bone cysts, tibial or talar components subsidence, polyethylene component wear or failure were observed. No salvation procedures were required in this series. DISCUSSION: This study results corroborates literature data showing great improvements in pain, functional pattern, and movement. CONCLUSION: Infinity Ankle Arthroplasty is a safe and reproducible procedure with good outcomes at a short-term follow-up. LEVEL OF EVIDENCES: 4 - Case series.


Assuntos
Artroplastia de Substituição do Tornozelo , Prótese Articular , Masculino , Humanos , Feminino , Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/métodos , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Radiografia
2.
Ann Intern Med ; 175(12): 1648-1657, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36375147

RESUMO

BACKGROUND: End-stage ankle osteoarthritis causes severe pain and disability. There are no randomized trials comparing the 2 main surgical treatments: total ankle replacement (TAR) and ankle fusion (AF). OBJECTIVE: To determine which treatment is superior in terms of clinical scores and adverse events. DESIGN: A multicenter, parallel-group, open-label randomized trial. (ISRCTN registry number: 60672307). SETTING: 17 National Health Service trusts across the United Kingdom. PATIENTS: Patients with end-stage ankle osteoarthritis, aged 50 to 85 years, and suitable for either procedure. INTERVENTION: Patients were randomly assigned to TAR or AF surgical treatment. MEASUREMENTS: The primary outcome was change in Manchester-Oxford Foot Questionnaire walking/standing (MOXFQ-W/S) domain scores between baseline and 52 weeks after surgery. No blinding was possible. RESULTS: Between 6 March 2015 and 10 January 2019, a total of 303 patients were randomly assigned; mean age was 68 years, and 71% were men. Twenty-one patients withdrew before surgery, and 281 clinical scores were analyzed. At 52 weeks, the mean MOXFQ-W/S scores improved for both groups. The adjusted difference in the change in MOXFQ-W/S scores from baseline was -5.6 (95% CI, -12.5 to 1.4), showing that TAR improved more than AF, but the difference was not considered clinically or statistically significant. The number of adverse events was similar between groups (109 vs. 104), but there were more wound healing issues in the TAR group and more thromboembolic events and nonunion in the AF group. The symptomatic nonunion rate for AF was 7%. A post hoc analysis suggested superiority of fixed-bearing TAR over AF (-11.1 [CI, -19.3 to -2.9]). LIMITATION: Only 52-week data; pragmatic design creates heterogeneity of implants and surgical techniques. CONCLUSION: Both TAR and AF improve MOXFQ-W/S and had similar clinical scores and number of harms. Total ankle replacement had greater wound healing complications and nerve injuries, whereas AF had greater thromboembolism and nonunion, with a symptomatic nonunion rate of 7%. PRIMARY FUNDING SOURCE: National Institute for Health and Care Research Heath Technology Assessment Programme.


Assuntos
Artroplastia de Substituição do Tornozelo , Osteoartrite , Masculino , Humanos , Idoso , Feminino , Artroplastia de Substituição do Tornozelo/efeitos adversos , Artroplastia de Substituição do Tornozelo/métodos , Articulação do Tornozelo/cirurgia , Tornozelo/cirurgia , Medicina Estatal , Resultado do Tratamento , Artrodese/efeitos adversos , Artrodese/métodos
3.
J Foot Ankle Surg ; 57(2): 353-356, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29284576

RESUMO

Total ankle arthroplasty has become an increasingly used alternative to ankle arthrodesis for the treatment of end-stage ankle arthritis. However, despite progressive technological advances and the advent of multiple commercial implant systems, some concern remains for the relatively high complication and failure rates. The objective of the present investigation was to perform a systematic review of the incidence of complications in obese patients undergoing total ankle arthroplasty. We performed a review of electronic databases with the inclusion criteria of retrospective case series, retrospective clinical cohort analyses, and prospective clinical trials with ≥15 total participants, a mean follow-up period of ≥12 months, ≥1 defined cohort with a body mass index of ≥30 kg/m2, and a reported incidence rate of complications requiring revisional surgery at the final follow-up point. Four studies met our inclusion criteria, with a total of 400 implants analyzed. Of these, ≥71 (17.8%) developed a complication requiring a revisional surgical procedure. The most commonly reported surgeries were revision of the metallic components and ankle gutter debridement. It is our hope that our investigation will allow foot and ankle surgeons to more effectively communicate the perioperative risk to their patients during the education and consent process.


Assuntos
Artroplastia de Substituição do Tornozelo/efeitos adversos , Índice de Massa Corporal , Obesidade/complicações , Osteoartrite/cirurgia , Complicações Pós-Operatórias/cirurgia , Adulto , Idoso , Artroplastia de Substituição do Tornozelo/métodos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Prognóstico , Estudos Prospectivos , Reoperação/métodos , Reoperação/estatística & dados numéricos , Medição de Risco , Resultado do Tratamento
4.
J Foot Ankle Surg ; 55(4): 868-73, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26884264

RESUMO

Subsidence of the talar component results in significant morbidity after total ankle replacement. When recognized, prompt revision could be needed to preserve the function of the implant; however, this is not always the case. In situations in which the implant cannot be revised, tibiotalocalcaneal arthrodesis might be necessary to salvage the extremity. The purpose of the present report is to describe the use of a custom titanium alloy truss to fill a bony void created by explantation of the implant components. Total ankle replacement was performed as the initial surgery to address end-stage osteoarthritis. Two years after the index procedure, the patient underwent revision of the polyethylene and talar components with subtalar arthrodesis secondary to progressive subtalar osteoarthritis and talar subsidence. The implant subsequently became infected and was removed. The patient underwent re-implantation after the infection had resolved, but significant talar subsidence required conversion to a tibiotalocalcaneal arthrodesis with a custom titanium alloy truss and retrograde intramedullary nail. At the most recent follow-up appointment, the patient was weightbearing on a stable extremity and pain free. Radiographic examination confirmed appropriate implant alignment and evidence of bone formation throughout the titanium truss. Although our results are restricted to a single case with initial, limited follow-up data, combining sound structural mechanics with an open architecture and unique texture, the custom titanium truss appears to maintain the limb length and promote healing across a large void.


Assuntos
Artrodese/instrumentação , Artroplastia de Substituição do Tornozelo/efeitos adversos , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Terapia de Salvação/instrumentação , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Artrodese/métodos , Artroplastia de Substituição do Tornozelo/métodos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico por imagem , Osteoartrite/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Radiografia/métodos , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica , Reoperação/métodos , Medição de Risco , Terapia de Salvação/métodos , Titânio , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA