Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Arq. bras. oftalmol ; 82(5): 381-388, Sept.-Oct. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019440

RESUMO

ABSTRACT Purpose: To evaluate the effectiveness in in­traocular pressure reduction and safety of micropulse trans­scleral diode cyclophotocoagulation in refractory glaucoma. Methods: We prospectively evaluated a case series of 21 eyes of 21 consecutive patients with refractory glaucoma treated with micropulse transscleral diode cyclophotocoagulation at 12-month follow-up. The total treatment time was at the discretion of the surgeon, considering baseline and target intraocular pressure and glaucoma diagnosis. Intraocular pressure, inflammation, visual acuity, and number of medications were monitored. Success was defined as intraocular pressure between 6 and 21 mmHg and/or 30% reduction from baseline intraocular pressure with or without the use of antiglaucoma medications. Visual acuity loss was defined as a loss of ≥2 lines of vision on the Snellen chart or a ≥2-level decrease in visual function in patients with nonmeasurable chart acuity. Results: The mean age was 61.04 ± 12.99 years, and 11 (52.4%) patients were male, with most (95%) patients showing low visual acuity at baseline (count fingers or worse). The mean intraocular pressure was 33.38 ± 15.95 mmHg, and the mean number of medications was 3.5 ± 1.1 at baseline. After 1, 3, 6, and 12 months, 76.19%, 57.14%, 55.56%, and 66.67%, respectively, of the patients were classified as treatment successes. Seven (33.3%) patients required new laser treatment and were considered treatment failures. The mean intraocular pressure reduction was 44.72% ± 29.72% in the first week and 41.59% ± 18.93% at the end of follow-up (p=0.006). The mean number of medications significantly dropped to 2.00 ± 1.7 at the 12-month visit (p=0.044). Complications included hypotony (4.8%), intraocular inflammation after 1 month (19%), and visual acuity loss (4.8%). Conclusions: Micropulse transscleral diode cyclophotocoagulation was safe and effective for reducing intraocular pressure in eyes with refractory and advanced glaucoma, with reduced need for ocular antihypertensive medication.


RESUMO Objetivo: Avaliar a eficácia na redução da pressão intraocular e na segurança da ciclofotocoagulação com laser de diodo transescleral em glaucoma refratário. Métodos: Avaliamos prospectivamente uma série de casos de 21 olhos de 21 pacientes com glaucoma refratário tratados com ciclofotocoagulação com laser de diodo transescleral com acompanhamento por 12 meses. O tempo total de tratamento ficou a critério do cirurgião, considerando a pressão intraocular inicial e alvo e o tipo de glaucoma. Pressão intraocular, inflamação, acuidade visual e número de medicamentos foram monitorados. O sucesso foi definido como pressão intraocular entre 6 e 21 mmHg e/ou redução de 30% da pressão intraocular basal com ou sem o uso de medicamentos glaucomatosos. Perda da acuidade visual foi definida como perda de ≥2 linhas de visão na tabela de Snellen ou uma diminuição de ≥ 2 níveis na função visual em pacientes com acuidade do gráfico não mensurável. Resultados: A idade média foi de 61,04 ± 12,99 anos e 11 (52,4%) pacientes eram do sexo masculino, com a maioria (95%) dos pacientes apresentando baixa acuidade visual inicialmente (conta dedos ou pior). A pressão intraocular média foi de 33,38 ± 15,95 mmHg, e o número médio de medicamentos foi de 3,5 ± 1,1, no início do estudo. Após 1, 3, 6 e 12 meses, 76,19%, 57,14%, 55,56% e 66,67%, respectivamente, dos pacientes foram classificados como sucesso do tratamento. Sete (33,3%) pacientes necessitaram de novo tratamento com laser e foram considerados falhas no tratamento. A redução média da pressão intraocular foi de 44,72% ± 29,72% na primeira semana e 41,59% ± 18,93% no final do seguimento (p=0,006). O número médio de medicamentos diminuiu significativamente para 2,00 ± 1,7 na visita de 12 meses (p=0,044). As complicações incluíram hipotonia (4,8%), inflamação intraocular após 1 mês (19%) e perda de acuidade visual (4,8%). Conclusões: A ciclofotocoagulação com laser de diodo transescleral foi segura e eficaz para reduzir a pressão intraocular em olhos com glaucoma refratário e avançado, com necessidade reduzida de hipotensores oculares.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Glaucoma/cirurgia , Fotocoagulação a Laser/métodos , Acuidade Visual , Glaucoma/fisiopatologia , Glaucoma Neovascular/cirurgia , Corpo Ciliar/cirurgia , Corpo Ciliar/fisiopatologia , Estudos Prospectivos , Fotocoagulação a Laser/instrumentação , Pressão Intraocular
2.
Arq Bras Oftalmol ; 82(5): 381-388, 2019 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-31271570

RESUMO

PURPOSE: To evaluate the effectiveness in in-traocular pressure reduction and safety of micropulse trans-scleral diode cyclophotocoagulation in refractory glaucoma. METHODS: We prospectively evaluated a case series of 21 eyes of 21 consecutive patients with refractory glaucoma treated with micropulse transscleral diode cyclophotocoagulation at 12-month follow-up. The total treatment time was at the discretion of the surgeon, considering baseline and target intraocular pressure and glaucoma diagnosis. Intraocular pressure, inflammation, visual acuity, and number of medications were monitored. Success was defined as intraocular pressure between 6 and 21 mmHg and/or 30% reduction from baseline intraocular pressure with or without the use of antiglaucoma medications. Visual acuity loss was defined as a loss of ≥2 lines of vision on the Snellen chart or a ≥2-level decrease in visual function in patients with nonmeasurable chart acuity. RESULTS: The mean age was 61.04 ± 12.99 years, and 11 (52.4%) patients were male, with most (95%) patients showing low visual acuity at baseline (count fingers or worse). The mean intraocular pressure was 33.38 ± 15.95 mmHg, and the mean number of medications was 3.5 ± 1.1 at baseline. After 1, 3, 6, and 12 months, 76.19%, 57.14%, 55.56%, and 66.67%, respectively, of the patients were classified as treatment successes. Seven (33.3%) patients required new laser treatment and were considered treatment failures. The mean intraocular pressure reduction was 44.72% ± 29.72% in the first week and 41.59% ± 18.93% at the end of follow-up (p=0.006). The mean number of medications significantly dropped to 2.00 ± 1.7 at the 12-month visit (p=0.044). Complications included hypotony (4.8%), intraocular inflammation after 1 month (19%), and visual acuity loss (4.8%). CONCLUSIONS: Micropulse transscleral diode cyclophotocoagulation was safe and effective for reducing intraocular pressure in eyes with refractory and advanced glaucoma, with reduced need for ocular antihypertensive medication.


Assuntos
Glaucoma/cirurgia , Fotocoagulação/métodos , Adulto , Idoso , Corpo Ciliar/fisiopatologia , Corpo Ciliar/cirurgia , Feminino , Glaucoma/fisiopatologia , Glaucoma Neovascular/cirurgia , Humanos , Pressão Intraocular , Fotocoagulação a Laser/métodos , Fotocoagulação/instrumentação , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acuidade Visual
5.
Rev. bras. oftalmol ; 70(5): 306-311, out. 2011. ilus
Artigo em Inglês | LILACS | ID: lil-606742

RESUMO

The authors conducted a review of classical and conflicting theories of accommodation and presbyopia. They make a critical comparison with the findings of magnetic resonance imaging (MRI) that have been developed in recent decades. Based on these studies, formulates a new approach on the subject, shifting the focus of the discussion of the lens to the posterior pole of the eye.


Os autores revisaram as teorias clássicas e conflitantes sobre acomodação e presbiopia. E as compararam criticamente com os achados de imagem por ressonância magnética (MRI) que têm se desenvolvido nas últimas décadas. Baseado nestes estudos, formulam uma nova abordagem sobre o tema, mudando o foco da discussão do cristalino para o polo posterior do olho.


Assuntos
Humanos , Presbiopia/fisiopatologia , Presbiopia/diagnóstico por imagem , Acomodação Ocular/fisiologia , Cristalino/fisiopatologia , Envelhecimento/fisiologia , Imageamento por Ressonância Magnética , Corpo Ciliar/fisiopatologia , Elasticidade , Emetropia/fisiologia , Modelos Teóricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA