Oper Dent ; 49(4): 421-431, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38978305

RESUMO

OBJECTIVES: This study evaluated the depth of cure (DoC) of eight resin-based composites (RBCs) photocured using one multipeak light-curing unit (LCU) on the standard output setting for the manufacturer's RBC recommended exposure time and at a higher irradiance for 3 seconds. METHODS: Three conventional RBCs: Tetric EvoCeram (Evo), Tetric N-Ceram (Cer), Tetric Prime (Pri); and five bulk-fill: Tetric N-Ceram Bulk Fill (CerBF), Opus Bulk Fill APS (OpusBF), Opus Bulk Fill Flow APS (OpusF), Tetric PowerFill (PFill) and Tetric PowerFlow (PFlow) were examined. Only PFill and PFlow are formulated to be photocured in 3 seconds. The RBCs were packed into a metal mold and photocured using a Bluephase PowerCure LCU for the RBC manufacturer's recommended exposure time on the standard mode and using the 3-second high irradiance mode. After photocuring, the specimens were immersed in a solvent for 1 hour. The length of the remaining RBC was measured and divided by 2. Data were analyzed using two-way analysis of variance (ANOVA) followed by the Tukey post hoc multiple comparison test (α=0.05). RESULTS: There was no significant difference in the DoC values for PFill and PFlow when photocured using the 3-second high irradiance protocol compared to the lower irradiance standard mode protocol. All other RBCs had significantly lower DoC values (p<0.001) when photocured off-label using the 3-second high irradiance mode. CONCLUSION: Of the eight RBCs tested, only PFill and PFlow achieved the same DoC when the high irradiance 3-second curing method was used compared to when their longer lower irradiance protocol was used.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Teste de Materiais , Resinas Compostas/uso terapêutico , Humanos , Fatores de Tempo , Polimerização , Cura Luminosa de Adesivos Dentários/métodos , Materiais Dentários/uso terapêutico , Materiais Dentários/química , Metacrilatos , Propriedades de Superfície
2.
J Dent ; 149: 105246, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39025426

RESUMO

OBJECTIVE: To evaluate the postoperative sensitivity (POS), as well as the clinical performance of posterior restorations using a new chemically-cured bulk-fill composite (Stela Automix and Stela Capsule, SDI) comparing with a light-cured bulk-fill composite after 6 months. METHODS: Fifty-five participants with at least three posterior teeth needing restoration were recruited. A total of 165 restorations were performed on Class I or Class II cavities. After the application of Stela primer, the chemically-cured composite (Stela Automix or Stela Capsule) was inserted. For the light-cured composite group, a universal adhesive (Scotchbond Universal) was applied with a bulk-fill composite (Filtek One). Participants were evaluated for spontaneous and stimulated POS in the baseline, after 48 h, 7 days, and 6 months. Additionally, each restoration was assessed using the updated version of FDI criteria after 6 months. The differences in the proportions of the groups were compared by Cochran test statistics (α = 0.05). RESULTS: Both chemically-cured composites showed a lower risk of POS compared to the light-cured composite at baseline and up to 48 h (p < 0.04). A significantly lower surface luster and texture was observed for the Stela Capsule composite compared to the light-cured bulk-fill composite (baseline and 6 months; p = 0.03). A significant color mismatch was observed for the light-cured bulk-fill composite compared to the chemically-cured composites (baseline and 6 months; p = 0.03). No significant differences were observed in any other item evaluations (p > 0.05). CONCLUSION: Chemically-cured composites exhibit lower postoperative sensitivity and less color mismatch compared to a light-cured bulk-fill composite after 6 months of clinical service. CLINICAL SIGNIFICANCE: The chemically-cured composites appear to be an appealing option for restoring posterior teeth, as they exhibit lower postoperative sensitivity compared to a light-cured bulk-fill composite, both at baseline and up to 48 h, and less color mismatch.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Sensibilidade da Dentina , Humanos , Resinas Compostas/química , Resinas Compostas/uso terapêutico , Restauração Dentária Permanente/métodos , Feminino , Masculino , Método Duplo-Cego , Adulto , Pessoa de Meia-Idade , Cura Luminosa de Adesivos Dentários , Materiais Dentários/química , Cimentos de Resina/química , Adulto Jovem , Dente Molar
3.
Eur J Oral Sci ; 132(4): e12990, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38698528

RESUMO

This study examined the effect of high irradiance and short exposure times on the depth of cure of six resin-based composites (RBCs). Bluephase PowerCure and the Valo X light-curing units (LCUs) were used to photocure bulk-fill RBCs for their recommended exposure times: Admira Fusion x-tra (AFX/20s), Aura Bulk Fill (ABF/20s), Filtek One Bulk Fill (FOB/20s), Opus Bulk Fill APS (OBF/30s), Tetric EvoCeram Bulk Fill (TEC/10s) and Tetric PowerFill (TPF/10s). In addition, all bulk-fill RBCs were tested for depth of cure with one short 3 s exposure time from the Bluephase PowerCure or the Valo X in the Xtra Power mode. The RBCs (n = 10 per RBC) were inserted into a 4 mm diameter metal mold and covered by a polyester strip before being photocured. After 24 h of storage, uncured RBC was scraped away to determine the depth of cure of the RBCs. None of the RBCs achieved a 4 mm depth of cure. The depth of cure of TEC and TPF was unaffected by the exposure times (recommended or short) when using the Valo X. The depth of cure of AFX/20s, AFX/Xtra Power, ABF/Xtra Power, FOB/Xtra Power, and OBF/30s RBCs was greater when using Valo X compared to the Bluephase PowerCure. It was concluded that short exposure times can reduce depth of cure and should only be used for some RBCs.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Polimerização , Resinas Compostas/efeitos da radiação , Resinas Compostas/química , Fatores de Tempo , Humanos , Propriedades de Superfície
4.
Oper Dent ; 49(1): 43-51, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38180469

RESUMO

The rise in temperature in pulp tissues is related not only to heat transfer by high-irradiance light-curing units (LCUs), but also to restorative procedures. This research aimed to compare the rise in pulp temperature (PT) induced by three LCUs at each restorative step while considering the influence of resin composite shade and thickness. To accomplish this, the investigators used a proposed experimental model replicating pulp fluid circulation with a controlled, simulated intraoral temperature in bovine incisors. The recorded external and internal PT ranged from 36.7°C to 37.1°C and 32.7°C to 33.0°C, respectively. A significant decrease of internal temperature was recorded during class V preparation, followed by a progressive and representative rise of temperature in the subsequent restorative steps. The temperature was significantly higher during light curing of the adhesive system using Valo compared to light curing using Elipar and Radii Cal. However, none of the analyzed devices produced a temperature that exceeded the pulp tolerance limit (a temperature increase over 5.5°C). The paired test showed no significant difference in pulp temperature associated with the thickness of the increment of resin composite. However, shade was found to have more influence on the amount of energy absorbed by pulp tissue-A1 samples showed significantly higher temperature variation compared to samples using the A4 shade of resin composite. To conclude, the microcirculation and the performance of procedures under constant air-water flux dissipate the heat absorbed by the pulp. Additionally, the data suggest that all three LCUs analyzed can be safely used in clinical procedures, and that the resin composite shade may influence the amount of irradiance delivered to the tooth surface and represents a significant factor in pulp temperature variance.


Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Animais , Bovinos , Temperatura , Temperatura Alta , Resinas Compostas/uso terapêutico
5.
Dent Mater ; 40(1): 80-89, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37919111

RESUMO

OBJECTIVES: To evaluate the effect of mono and multi-wave light-curing units (LCUs) on the Knoop hardness of resin-based composites (RBC) that use different photoinitiators. METHODS: Central incisor-shaped specimens 12 mm long, 9 mm wide, and 1.5 mm thick were made from 2 RBCs that use different photoinitiators: Tetric N-Ceram (Ivoclar Vivadent) - and Vittra APS (FGM), both A2E shade. They were light-cured with 4 different LCUs: two claimed to be multi-wave - VALO Grand (Ultradent) and Emitter Now Duo (Schuster); and two were monowave - Radii Xpert (SDI) and Elipar DeepCure-L (3 M Oral Care) using 2 different light exposure protocols: one 40 s exposure centered over the specimen; and two 20 s light exposures that delivered light from two positions to better cover the entire tooth. 16 groups with 10 specimens in each group were made. The Knoop hardness (KH, kg/mm2) was measured at the top and bottom of the specimen in the center and at the cervical, incisal, mesial, and distal peripheral regions. The active tip diameters (mm) and spectral radiant powers (mW/nm) of the LCUs were measured with and without the interposition of the RBC, as well as the radiant exposure beam profiles (J/cm²) delivered to the top of the RBCs. The data was analyzed using Three-way ANOVA and Tukey's tests (α = 0.05). RESULTS: The VALO Grand (1029 mW) emitted twice the power of the Radii Xpert (500 mW). The KH values of VI and TN resin composite specimens were significantly affected by the LCU used (p < .001), the measurement location (p < .001), and the surface of the specimen (p < .001). LCUs with wider tip diameters produced greater Knoop hardness values at the peripheries of the 12 mm of long, 9 mm wide specimens. In general, the VALO Grand produced the highest KH values, followed by Elipar DeepCure-L, then by Radii Xpert. The Emitter Now Duo LCU produced the lowest values. Exposing the veneers from two locations reduced the differences between the LCUs and the effect of the measurement location. Only the VALO Grand could fully cover the composite veneer with light when the two locations were used. SIGNIFICANCE: The light tip must cover the entire restoration to photocure the RBC beneath the light tip.


Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Dureza , Teste de Materiais , Resinas Compostas , Materiais Dentários , Polimerização
6.
Braz Oral Res ; 37: e114, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37970934

RESUMO

The thickness and shade of a restoration will affect the transmission of light from the light-curing unit (LCU). This study determined the power (mW), spectral radiant power (mW/nm), and beam profile of different LCUs through various thicknesses and shades of a CAD-CAM resin composite (BRAVA Block, FGM). Five thicknesses: 0.5; 0.75; 1.0; 1.5, and 2.0 mm, in three shades: Bleach; A2 and A3.5 of a CAD-CAM resin (n = 5). Two single-peak LCUs: EL, Elipar DeepCure-S (3M Oral Care); and OP, Optilight Max (Gnatus), and one multiple-peak LCU: VL, VALO Grand (Ultradent), were used. The LCUs were positioned touching the surface of the BRAVA Block. The power and emission spectrum were measured using a fiberoptic spectrometer attached to an integrating sphere, and the beam profiles using a laser beam profiler. The effect of the material thickness on the light attenuation coefficients was determined. VL and EL delivered more homogeneous beam profiles than OP. The type of the BRAVA Block had a significant effect on the transmitted power, and wavelengths of transmitted light (p < 0.001). There was an exponential reduction in the power and emission spectrum as the thickness of the BRAVA Block increased (p < 0.001). The light transmission through the A2 shade was least affected by the thickness (p < 0.001). The attenuation coefficient was higher for the violet light and higher for A3.5 than the A2 or Bleach shades. No violet light from the VL could be detected at the bottom of 2.0 mm of the BRAVA Block.


Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Resinas Compostas , Desenho Assistido por Computador
7.
J Esthet Restor Dent ; 35(6): 968-979, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37560968

RESUMO

OBJECTIVE: To evaluate the accuracy of five brands of radiometers in reporting the irradiance (mW/cm2 ) from twelve brands of LCUs compared to a 'Gold Standard' (GS) reference obtained from a hand-held laboratory-grade radiometer. MATERIALS AND METHODS: The irradiance was measured from two examples of twelve brands of previously used LCUs on two examples of five brands of dental radiometers. The emission spectrum was also obtained. Irradiance data from each brand of LCU against each meter was analyzed using the Shapiro-Wilk test for normality. The irradiance values were subjected to a two-way ANOVA followed by Bonferroni tests for each LCU brand. Finally, a descriptive analysis was made using a 95% confidence interval around the mean irradiance. RESULTS: The power output from the LCUs ranged from 271 mW to 1005 mW. Among the tested radiometers, only the Bluephase Meter II could accurately report the irradiance from 11 out of the 12 brands of LCU evaluated in this study. When measured using the "GS" system, the mean irradiance values from the two examples of nine brands of previously used LCU were not always within ±10% of the irradiance values stated by the manufacturer. CONCLUSIONS: The mean irradiance values from 9 of the 12 brands of used LCUs were beyond ±10% of the irradiance values stated by the manufacturer. Only the Bluephase Meter II could accurately report the irradiance from 11 out of the 12 brands of LCU evaluated in this study. CLINICAL SIGNIFICANCE: There was a wide range in the power output from the LCUs tested. It was impossible to accurately measure the irradiance from all the LCUs using the dental radiometers examined. However, dental radiometers should still be used in dental offices to monitor the light output from LCUs and verify that they are working correctly before they are used on patients.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Humanos , Cura Luminosa de Adesivos Dentários , Radiometria , Teste de Materiais
8.
Oper Dent ; 48(3): 304-316, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36917633

RESUMO

OBJECTIVES: To analyze the effect of using the resin-based composite manufacturer's recommended exposure time on the degree of conversion (DC), Knoop hardness (KH), and elastic modulus (E) of conventional and bulk-fill resin-based composites (RBCs). METHODS: Three resin-based composites (RBCs) were tested: Tetric EvoCeram Bulk Fill (TET), Opus Bulk Fill APS (OPU), and RBC Vittra APS (VIT). They were photo-activated in 2 mm deep, 6 mm diameter molds for their recommended exposure times of 10 seconds, 20 seconds, or 40 seconds from four light-curing units (LCUs). Two delivered a single emission peak in the blue light region (Optilight Max and Radii-Cal) and two delivered multiple emission peaks in the violet and blue region (VALO Cordless and Bluephase G2). After 24 hours of dry storage at 37°C in the dark, the KH (Kgf/mm2), E (MPa) and DC (%) at the top and bottom surfaces of specimens (n=5) were measured and the results analyzed by 2-way analysis of variance (ANOVA) followed by a Tukey test (α=0.05). RESULTS: The irradiance (mW/cm2) and spectral irradiance (mW/cm2/nm) from the LCUs were reduced significantly (8-35%) after passing through 2.0 mm of RBC (p<0.001). The DC at the bottom of VIT and TET was less than at the top surface (p<0.001). OPU had the same DC at the top and bottom surface (p=0.341). The KH and E values at the top surface of VIT and TET were substantially higher than at the bottom (p<0.001). OPU exposed for 40 seconds achieved higher mechanical properties than TET that was photo-activated for 10 seconds (p<0.001). The opacity of different bulk-fill RBCs changed differently during the polymerization; OPU became more opaque, whereas TET became more transparent. When exposed for their recommended times, the 2 mm thick RBCs that used Ivocerin or the APS photoinitiator system were adequately photo-activated using either the single or multiple emission peak LCUs (p=0.341). CONCLUSION: After 24 hours' storage, all the 2 mm thick RBCs photo-cured in 6 mm diameter molds achieved a bottom-to-top hardness ratio of at least 80% when their recommended exposure times were used. TET, when photo-activated for 10 seconds, achieved lower mechanical properties than OPU that had been photo-activated for 40 seconds. The change in opacity of the RBCs was different during photo-activation.


Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Cura Luminosa de Adesivos Dentários/métodos , Teste de Materiais , Materiais Dentários , Resinas Compostas , Dureza , Polimerização , Propriedades de Superfície
9.
J Esthet Restor Dent ; 35(4): 705-716, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36738181

RESUMO

OBJECTIVE: To evaluate the in vitro pulpal temperature rise (ΔT) within the pulp chamber when low- and high-viscosity bulk-fill resin composites are photo-cured using laser or contemporary light curing units (LCUs). MATERIALS AND METHODS: The light output from five LCUs was measured. Non-retentive Class I and V cavities were prepared in one upper molar. Two T-type thermocouples were inserted into the pulp chamber. After the PT values reached 32°C under simulated pulp flow (0.026 mL/min), both cavities were restored with: Filtek One Bulk Fill (3 M), Filtek Bulk Fill Flow (3 M), Tetric PowerFill (Ivoclar Vivadent), or Tetric PowerFlow (Ivoclar Vivadent). The tooth was exposed as follows: Monet Laser (1 and 3 s), PowerCure (3 and 20 s), PinkWave (3 and 20 s), Valo X (5 and 20 s) and SmartLite Pro (20 s). The ΔT data were subjected to one-way ANOVA followed by Scheffe's post hoc test. RESULTS: Monet 1 s (1.9 J) and PinkWave 20 s (30.1 J) delivered the least and the highest amount of energy, respectively. Valo X and PinkWave used for 20 s produced the highest ΔT values (3.4-4.1°C). Monet 1 s, PinkWave 3 s, PowerCure 3 s (except FB-Flow) and Monet 3 s for FB-One and TP-Fill produced the lowest ΔT values (0.9-1.7°C). No significant differences were found among composites. CONCLUSIONS: Short 1- to 3-s exposures produced acceptable temperature rises, regardless of the composite. CLINICAL SIGNIFICANCE: The energy delivered to the tooth by the LCUs affects the temperature rise inside the pulp. The short 1-3 s exposure times used in this study delivered the least amount of energy and produced a lower temperature rise. However, the RBC may not have received sufficient energy to be adequately photo-cured.


Assuntos
Lâmpadas de Polimerização Dentária , Cárie Dentária , Humanos , Temperatura , Cura Luminosa de Adesivos Dentários , Resinas Compostas , Materiais Dentários , Teste de Materiais , Polimerização
10.
J Esthet Restor Dent ; 35(4): 698-704, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36655725

RESUMO

OBJECTIVE: To evaluate the effect of delayed light-curing of dual-cure bulk-fill composites on internal adaptation and microhardness (KHN) in depth. MATERIALS AND METHODS: Bulk-fill composites were placed in 35 box-shaped preparations and cured according to the following protocols (n = 5): Filtek Bulk-Fill light-cured immediately after insertion (FBF); Bulk-EZ light-cured immediately after insertion (BEZ-I); Bulk-EZ light-cured 90 s after insertion (BEZ-DP); Bulk-EZ self-cured (BEZ-SC); HyperFIL light-cured immediately after insertion (HF-I); HyperFIL light-cured 90 s after insertion (HF-DP); HyperFIL self-cured (HF-SC). After 24 h, the samples were axially sectioned, and the internal adaptation was evaluated using replicas under a scanning electron microscope. The KHN was evaluated at six depths (0.3 mm, 1 mm, 2 mm, 3 mm, 4 mm, and 5 mm). The statistical analysis was performed using α = 0.05. RESULTS: The KHN significantly decreased with depth, except in self-curing mode, when it was similar at all depths. Delayed light-curing significantly increased the KHN at higher depths. The internal adaptation was material-dependent. Light-curing did not influence the internal adaptation of HyperFIL, whereas delayed light-curing significantly reduced the internal gaps (%) of Bulk-EZ. CONCLUSION: Delayed light-curing improved the depth of cure of dual-cure resin composites. Light-curing did not influence the internal adaptation of HyperFIL, but delayed light-curing improved the internal adaptation of Bulk-EZ. CLINICAL SIGNIFICANCE: Light-curing is fundamental for improving the mechanical properties of dual-cure resin composites. Moreover, depending on the dual-cure resin composite, the delay in light-curing can reduce the internal gaps.


Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Resinas Compostas , Teste de Materiais , Polimerização