Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 283
Filtrar
1.
Arq Bras Oftalmol ; 88(1): e20230103, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39109740

RESUMO

PURPOSE: This study aimed to compare the safety and effectiveness of intraocular pressure reduction between micropulse transscleral cyclophotocoagulation and "slow cook" transscleral cyclophotocoagulation in patients with refractory primary open-angle glaucoma. METHODS: We included patients with primary open angle glaucoma with at least 12 months of follow-up. We collected and analyzed data on the preoperative characteristics and postoperative outcomes. The primary outcomes were a reduction of ≥20% of the baseline value (criterion A) and/or intraocular pressure between 6 and 21 mmHg (criterion B). RESULTS: We included 128 eyes with primary open-angle glaucoma. The preoperative mean intraocular pressure was 25.53 ± 6.40 and 35.02 ± 12.57 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean intraocular pressure was reduced significantly to 14.33 ± 3.40 and 15.37 ± 5.85 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups at the last follow-up, respectively (p=0.110). The mean intraocular pressure reduction at 12 months was 11.20 ± 11.46 and 19.65 ± 13.22 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The median preoperative logMAR visual acuity was 0.52 ± 0.69 and 1.75 ± 1.04 in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean visual acuity variation was -0.10 ± 0.35 and -0.074 ± 0.16 in the micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p=0.510). Preoperatively, the mean eye drops were 3.44 ± 1.38 and 2.89 ± 0.68 drugs in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p=0.017), but those were 2.06 ± 1.42 and 1.02 ± 1.46 at the end of the study in the "slow cook" and micropulse transscleral cyclophotocoagulation groups, respectively (p<0.001). The success of criterion A was not significant between both groups. Compared with 11 eyes (17.74%) in the "slow cook" transscleral cyclophotocoagulation group, 19 eyes (28.78%) in the micropulse transscleral cyclophotocoagulation group showed complete success (p=0.171). For criterion B, 28 (42.42%) and 2 eyes (3.22%) showed complete success after micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p<0.001). CONCLUSION: Both techniques reduced intraocular pressure effectively.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Fotocoagulação a Laser , Lasers Semicondutores , Esclera , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Fotocoagulação a Laser/métodos , Idoso , Lasers Semicondutores/uso terapêutico , Esclera/cirurgia , Acuidade Visual , Adulto , Seguimentos , Período Pós-Operatório , Corpo Ciliar/cirurgia , Fatores de Tempo
2.
Curr Eye Res ; 49(10): 1068-1073, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38856046

RESUMO

PURPOSE: This study describes a prototype developed for aphakia without capsular support (AWCS) and its proof of concept. METHODS: This descriptive study used a 3D software to create and analyze virtual prototypes before manufacturing. A nylon-6/nylon-6.6 copolymer filament and a 3D printer were used for prototyping. A device implantation technique was developed using a 23-gauge hypodermic needle. Two opposing markings, 2 mm posterior to the limbus, were made to determine the location of the scleral punctures and the final position of the device. After adequate centralization and positioning of the device, its haptics were cut and cauterized to generate thermal modeling of the extremity and allow the thickening of the tips (flange), serving as an anchoring mechanism to the sclera. The efficacy and adequacy of the technique and device were then evaluated. RESULTS: Vitreous tissue extrusion was not observed during the sclerotomy. The device was well fixed to the sclera; however, adequate IOL stability and centralization still needed to be achieved. The surgeon evaluated the adequacy of all the other devices' characteristics. CONCLUSIONS: The development of a technology prototype for correcting AWCS was possible. Although the proposed prototype met most of the established concept guidelines, the stability of the IOL position remains challenging.


Assuntos
Afacia Pós-Catarata , Humanos , Afacia Pós-Catarata/cirurgia , Afacia Pós-Catarata/fisiopatologia , Cápsula do Cristalino/cirurgia , Lentes Intraoculares , Esclerostomia , Implante de Lente Intraocular/métodos , Esclera/cirurgia , Afacia/cirurgia , Impressão Tridimensional , Desenho de Prótese , Acuidade Visual/fisiologia
3.
J Cataract Refract Surg ; 50(5): 505-510, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651698

RESUMO

PURPOSE: To compare flange depth for a modified scleral pocket (SP) vs no scleral pocket (NSP) technique (Yamane technique) for intrascleral intraocular lens (IOL) fixation. SETTING: Instituto de Oftalmología Santa Fe, Santa Fe, Argentina. DESIGN: Prospective, randomized, single-surgeon, observational study. METHODS: Eyes with aphakia and no capsular support were included. They were divided into 2 groups: one was programmed for a double-needle flanged intrascleral IOL fixation as originally described by Shin Yamane with NSP and the second group had a modified SP technique. Flange depth was measured with anterior-segment optical coherence tomography (AS-OCT) at 1 month, 3 months, 6 months, and 12 months postoperatively, and the results were compared. RESULTS: Each group comprised 18 eyes of 18 patients, giving a total of 36 flanges per group. The groups were comparable preoperatively. At 12 months, uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were not statistically different for both groups (P = .333; P = .448). Spherical equivalent (SEQ) was not significantly different between groups at 12 months postoperatively (P = .078). AS-OCT revealed a significantly deeper flange position for the SP group at 1 month, 3 months, 6 months, and 12 months postoperatively (P < .05). CONCLUSIONS: When performing a double-needle intrascleral IOL fixation in aphakic eyes with no capsular support, a modified scleral pocket technique provides a significantly deeper flange position with no difference in CDVA or SEQ 12 months postoperatively.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Esclera , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Esclera/cirurgia , Implante de Lente Intraocular/métodos , Estudos Prospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Afacia Pós-Catarata/cirurgia , Afacia Pós-Catarata/fisiopatologia , Retalhos Cirúrgicos , Técnicas de Sutura , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia
4.
Arq Bras Oftalmol ; 87(2): e20220046, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38451677

RESUMO

The creation of a scleral flap during trabeculectomy can be complicated by a buttonhole, partial amputation at the limbus, and extensive thinning. In some cases, the procedure must be aborted to prevent more serious postoperative complications. This report describes a technique of converting complicated trabeculectomy into ab externo cyclodialysis. A 41-year-old patient with congenital glaucoma presented with a perforated scleral wall with the choroidal tissue exposed during the dissection of the partial-thickness scleral flap. By using a Barraquer cyclodialysis spatula through the scleral perforation, the choroid was separated from the sclera up to the scleral spur over 30° into the anterior chamber. The sclera and conjunctiva/Tenon were sutured with 10-0 nylon single sutures. Two months later, the intraocular pressure was reduced to 16 mmHg with no hypotensive topical medications. This case illustrates an alternative approach to managing a flap-related perioperative complication in trabeculectomy, which yielded good early results.


Assuntos
Glaucoma , Trabeculectomia , Humanos , Adulto , Trabeculectomia/efeitos adversos , Esclera/cirurgia , Câmara Anterior , Túnica Conjuntiva/cirurgia , Anti-Hipertensivos , Glaucoma/cirurgia
5.
Arq Bras Oftalmol ; 87(2): e20220306, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38451682

RESUMO

PURPOSE: As superotemporal implantation of the Ahmed glaucoma valve is not always feasible in cases of refractory glaucoma, this study examined the characteristics and surgical outcomes of cases in which the valve was implanted in a nonsuperotemporal quadrant using a modified long scleral tunnel technique. METHODS: This retrospective case-control study included 37 eyes with nonsuperotemporal quadrant--Ahmed glaucoma valve implantation in Group 1 and 69 eyes with superotemporal Ahmed glaucoma valve implantation in Group 2. The demographic characteristics of these groups, surgical outcomes, including complications, further surgical interventions, and surgical success rates were compared. Surgical success was defined as an intraocular pressure not exceeding 21 mmHg, accompanied by a minimum reduction of 20% in intraocular pressure from the baseline without any additional intraocular pressure-lowering procedures, and the absence of light perception loss or phthisis bulbi. RESULTS: Group 1 had significantly higher numbers of eyes with secondary glaucoma and preoperative surgical procedures than Group 2 (p<0.05). Both groups had mean preoperative intraocular pressure values, and mean intraocular pressure values at the last visit of 34.2 and 27.9 months, 35.5 ± 1.5 and 35.8 ± 1.2 mmHg, and 14.5 ± 5 and 14.9 mmHg, respectively. Although both groups had 70.2% and 75.8% as their five-year cumulative probability of success, respectively, the rates of complications, revisional surgery, and additional surgical procedures did not differ significantly (p>0.05). CONCLUSION: The modified long scleral tunnel technique for Ahmed glaucoma valve implantation in nonsuperotemporal quadrants achieves intraocular pressure control and complication rates comparable to superotemporal implantation.


Assuntos
Glaucoma , Pressão Intraocular , Humanos , Estudos de Casos e Controles , Estudos Retrospectivos , Glaucoma/cirurgia , Esclera/cirurgia
6.
Vet Ophthalmol ; 27(1): 17-29, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36872572

RESUMO

OBJECTIVE: Scleral ossicle rings of reptiles have endoskeletal functions that are not completely understood. Moreover, descriptive reports on the anatomy of those rings are scarce. We tried to make an anatomical description that could contribute to a better understanding of their functions. ANIMAL STUDIED AND PROCEDURES: We quantified, histologically characterized and evaluated the morphobiometry of the scleral ossicles, and measured the aditus orbitae of 25 sea turtle (Chelonia mydas) heads. RESULTS: The aditus orbitae represented about one-third of the total head length and the mean area of the internal opening of each ring was up to 8.37% of the aditus orbitae area. The mean internal diameter of the rings (6.32 mm) was characteristic of scotopic species and the most frequent number of ossicles per ring varied between 11 and 12. Two new classifications were proposed for the ossicle types: plus-Verzahnung (+V) and minus-Verzahnung (-V). The bone tissue revealed a lamellar arrangement typical of compact and resistant bones. CONCLUSION: The obtained data may be used to support and expand the understanding of functions, animal activity patterns, distinctions between taxa and taphonomic interpretations.


Assuntos
Tartarugas , Animais , Esclera , Osso e Ossos
8.
J Glaucoma ; 32(8): 695-700, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37172013

RESUMO

PRCIS: Slow-coagulation CW-TSCPC is an efficacious, relatively safe, and non-incisional laser treatment option as an initial surgical glaucoma management choice, in secondary aphakic adult glaucoma that is medically uncontrolled. PURPOSE: This study evaluates the outcomes of slow-coagulation continuous wave transscleral cyclophotocoagulation (CW-TSCPC) laser for treating secondary aphakic adult glaucoma after complicated cataract surgery as a primary surgical intervention. MATERIALS AND METHODS: A retrospective chart review of adult aphakic eyes with medically uncontrolled glaucoma underwent slow-coagulation CW-TSCPC as a primary surgical glaucoma intervention was performed. Surgical success was the primary outcome measure. Success was defined as postoperative intraocular pressure (IOP) between 6 and 21 mm Hg with ≥20% reduction compared with baseline and no need for further glaucoma surgeries or development of vision-threatening complications. The secondary outcomes included changes in IOP, glaucoma medication numbers, visual acuity, and postoperative complications during the first year after laser treatment after laser treatment. RESULTS: This study included 41 eyes of 41 patients. The mean age of study participants was 66.7±13.1 years, with a mean follow-up duration of 19±3.5 months. At one year, the success rate was 63.4%. A statistically significant reduction of the IOP was observed, with the mean IOP decreasing from 29.6±5.8 mm Hg with a mean of 3.9±1.0 medications at baseline to a mean of 19.0±6.4 mm Hg with a mean of 2.5±1.2 medications at 12 months ( P <0.001). Four eyes received CW-TSCPC retreatment, and 2 eyes required incisional glaucoma surgeries. Reported postoperative complications included: visual acuity decline ≥2 lines in 7 eyes, iritis in 6 eyes, hyphema in 5 eyes, cystoid macular edema in 2 eyes, and transient hypotony in 1 eye. CONCLUSION: Slow-coagulation CW-TSCPC is an efficacious, relatively safe, and non-incisional laser treatment option as an initial surgical glaucoma management choice, in secondary aphakic adult glaucoma that is medically uncontrolled.


Assuntos
Glaucoma , Pressão Intraocular , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Fotocoagulação a Laser , Resultado do Tratamento , Glaucoma/complicações , Glaucoma/cirurgia , Corpo Ciliar/cirurgia , Esclera/cirurgia
9.
J Cataract Refract Surg ; 49(6): 565-570, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36745851

RESUMO

PURPOSE: To assess the long-term (5-year) results and complications of the double-flanged polypropylene technique in patients with capsular tension segment fixation, nonfoldable intraocular lens (IOL) scleral fixation, and foldable IOL scleral fixation. SETTING: Santa Casa de Belo Horizonte and Centro Oftalmológico de Minas Gerais. DESIGN: Prospective case series. METHODS: Eyes that underwent treatment using the double-flanged polypropylene technique between September 2016 to September 2021 were included. LogMAR visual acuity was recorded, as well as complications such as long-term polypropylene resistance, conjunctival erosion, conjunctival inflammation, flange exposure, internalization, endophthalmitis, retinal detachment, and cystoid macular edema. RESULTS: 71 eyes of 61 patients were evaluated. The mean follow-up period for these eyes was 28.2 ± 14.3 (min: 4; max: 60; median: 26) months. 173 flanges were performed. 13 cases with sub-Tenon flanges (7.5%) were observed. 5 exposed flanges (2.89%), presented after a mean of 1.8 weeks postoperatively, were observed. 1 patient with large flanges presented with conjunctival inflammation and hyperemia. 2 late internalized flanges (1.1%) and 2 recently internalized flanges (1.1%) were observed. 3 eyes (4.22%) had retinal detachment. Moreover, cystoid macular edema was detected in 3 eyes (4.22%). No cases of endophthalmitis were observed. CONCLUSIONS: The double-flanged technique was proven to be stable when the correct technical procedure was followed. However, complications can be observed, especially with short scleral tunnels and in eyes where the flanges were not buried inside the sclera.


Assuntos
Endoftalmite , Lentes Intraoculares , Edema Macular , Descolamento Retiniano , Humanos , Implante de Lente Intraocular/métodos , Polipropilenos , Descolamento Retiniano/cirurgia , Esclera/cirurgia , Endoftalmite/cirurgia , Inflamação , Estudos Retrospectivos , Técnicas de Sutura , Complicações Pós-Operatórias/cirurgia
10.
Retina ; 43(12): 2166-2169, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36729566

RESUMO

PURPOSE: To demonstrate a mathematical analogy between the Pythagorean theorem using the axial a-scan measurement, i.e., the distance between the central cornea and the sclerotomy, and the lengths of the forceps in eyes of patients with all axial lengths. METHODS: We used the Pythagorean equation (c 2 = a 2 + b 2 ) to calculate the adequate shaft length of the forceps to use in macular surgery, especially in highly myopic eyes, where c 2 represents the axial length (hypotenuse); b 2 the sum of the corneal ray and distance between the corneal limbus and the sclerotomy (base side); and a 2 the distance between the sclerotomy and the fovea (perpendicular side). RESULTS: We reproduced the cosine law to estimate the distance between the sclerotomy and the fovea. The distance between the sclerotomy and the foveal area is shorter than the axial length and can become smaller based on the distance from the sclerotomy to the corneal limbus. CONCLUSION: This simple mathematical formula is useful when performing surgery in highly myopic eyes, in which there can be difficulties reaching the macular area.


Assuntos
Miopia , Tomografia de Coerência Óptica , Humanos , Miopia/cirurgia , Fóvea Central , Esclera
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA