Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Orthop Trauma ; 31(8): e247-e251, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28430720

RESUMO

OBJECTIVES: No studies have assessed the effects of parameters associated with insertion temperature in modern self-drilling external fixation pins. The current study assessed how varying the presence of irrigation, insertion speed, and force impacted the insertion temperatures of 2 types of standard and self-drilling external fixation half pins. METHODS: Seventy tests were conducted with 10 trials for 4 conditions on self-drilling pins, and 3 conditions for standard pins. Each test used a thermocouple inside the pin to measure temperature rise during insertion. RESULTS: Adding irrigation to the standard pin insertion significantly lowered the maximum temperature (P <0.001). Lowering the applied force for the standard pin did not have a significant change in temperature rise. Applying irrigation during the self-drilling pin tests dropped average rise in temperature from 151.3 ± 21.6°C to 124.1 ± 15.3°C (P = 0.005). When the self-drilling pin insertion was decreased considerably from 360 to 60 rpm, the temperature decreased significantly from 151.3 ± 21.6°C to 109.6 ± 14.0°C (P <0.001). When the force applied increased significantly, the corresponding self-drilling pin temperature increase was not significant. CONCLUSIONS: The standard pin had lower peak temperatures than the self-drilling pin for all conditions. Moreover, slowing down the insertion speed and adding irrigation helped mitigate the temperature increase of both pin types during insertion.


Assuntos
Pinos Ortopédicos/normas , Fixadores Externos/normas , Fixação de Fratura/instrumentação , Fixação de Fratura/métodos , Temperatura , Animais , Fenômenos Biomecânicos , Pinos Ortopédicos/tendências , Falha de Equipamento , Fixadores Externos/tendências , Humanos , Teste de Materiais , Fatores de Risco
2.
In. Schwarz, Richard; Brandsma, Wim. Surgical reconstruction rehabilitation in leprosy and other neuropathies. Kathmandu, Ekta Books, 2004. p.127-132, ilus.
Monografia em Inglês | Sec. Est. Saúde SP, HANSEN, Hanseníase, SESSP-ILSLACERVO, Sec. Est. Saúde SP | ID: biblio-1247038
3.
Rev. mex. ortop. traumatol ; 11(1): 38-41, ene.-feb. 1997. tab, ilus
Artigo em Espanhol | LILACS | ID: lil-227115

RESUMO

Entre mayo de 1992 y noviembre de 1994, se realizaron 236 cirugía para corección de genu varo en el Hospital de Traumatología y Ortopedía ®Lomas Verdes¼, de éstos, se seleccionaron 100 casos para un estudio comparativo prospectivo, tratando a 50 de ellos mediante técnica de Maquet y fijación externa no transfictiva, y 50 mediante fijación externa transfictiva, la deformidad promedio fue de 14.9 grado, el grado de artrosis y el dolor preoperatorio fueron moderados a severos en más de 75 por ciento de los casos, la técnica de la osteotomía fue estandarizada, solamente cambió el método de fijación, el tiempo quirúrgico fue menor con fijación no transfictiva, la infección se presntó en 24 por ciento de fijación transfictiva, la lesión del ciático poplíteo externo fue de 3.7 por ciento en fijación no transfictiva comparada con 13 por ciento de la transfictiva, el tiempo de consolidación fue similar, el dolor disminuyó en 77 por ciento de ambos grupos, la flexión promedio fue mayor en fijación no transfictiva, la corrección del eje mecánico fue similar, la marcha normal es similar, la anormal es mayor en la fijación transfictiva, los resultados globales señalan a la fijación tubular no transfictiva como una alternativa eficaz en sujetos menores de 60 años sin osteoporosis marcada


Assuntos
Humanos , Masculino , Feminino , Osteotomia/reabilitação , Osteotomia/tendências , Osteotomia/estatística & dados numéricos , Tíbia/cirurgia , Fixadores Externos/tendências , Fixadores Externos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA