Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 601
Filtrar
1.
Arq Bras Oftalmol ; 88(1): e20230103, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39109740

RESUMO

PURPOSE: This study aimed to compare the safety and effectiveness of intraocular pressure reduction between micropulse transscleral cyclophotocoagulation and "slow cook" transscleral cyclophotocoagulation in patients with refractory primary open-angle glaucoma. METHODS: We included patients with primary open angle glaucoma with at least 12 months of follow-up. We collected and analyzed data on the preoperative characteristics and postoperative outcomes. The primary outcomes were a reduction of ≥20% of the baseline value (criterion A) and/or intraocular pressure between 6 and 21 mmHg (criterion B). RESULTS: We included 128 eyes with primary open-angle glaucoma. The preoperative mean intraocular pressure was 25.53 ± 6.40 and 35.02 ± 12.57 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean intraocular pressure was reduced significantly to 14.33 ± 3.40 and 15.37 ± 5.85 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups at the last follow-up, respectively (p=0.110). The mean intraocular pressure reduction at 12 months was 11.20 ± 11.46 and 19.65 ± 13.22 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The median preoperative logMAR visual acuity was 0.52 ± 0.69 and 1.75 ± 1.04 in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean visual acuity variation was -0.10 ± 0.35 and -0.074 ± 0.16 in the micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p=0.510). Preoperatively, the mean eye drops were 3.44 ± 1.38 and 2.89 ± 0.68 drugs in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p=0.017), but those were 2.06 ± 1.42 and 1.02 ± 1.46 at the end of the study in the "slow cook" and micropulse transscleral cyclophotocoagulation groups, respectively (p<0.001). The success of criterion A was not significant between both groups. Compared with 11 eyes (17.74%) in the "slow cook" transscleral cyclophotocoagulation group, 19 eyes (28.78%) in the micropulse transscleral cyclophotocoagulation group showed complete success (p=0.171). For criterion B, 28 (42.42%) and 2 eyes (3.22%) showed complete success after micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p<0.001). CONCLUSION: Both techniques reduced intraocular pressure effectively.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Fotocoagulação a Laser , Lasers Semicondutores , Esclera , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Fotocoagulação a Laser/métodos , Idoso , Lasers Semicondutores/uso terapêutico , Esclera/cirurgia , Acuidade Visual , Adulto , Seguimentos , Período Pós-Operatório , Corpo Ciliar/cirurgia , Fatores de Tempo
2.
Lasers Med Sci ; 39(1): 205, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39088075

RESUMO

Mesenchymal stem cells can differentiate into specific cell lineages in the tissue repair process. Photobiomodulation with laser and LED is used to treat several comorbidities, can interfere in cell proliferation and viability, in addition to promoting responses related to the physical parameters adopted. Evaluate and compare the effects of laser and LED on mesenchymal cells, with different energy doses and different wavelengths, in addition to viability and wound closure. Mesenchymal stem cells derived from human adipocytes were irradiated with laser (energy of 0.5 J, 2 J and 4 J, wavelength of 660 nm and 830 nm), and LED (energy of 0.5 J, 2 J and 4 J, where lengths are 630 nm and 850 nm). The wound closure process was evaluated through monitoring the reduction of the lesion area in vitro. Viability was determined by analysis with Hoechst and Propidium Iodide markers, and quantification of viable and non-viable cells respectively Data distributions were analyzed using the Shapiro-Wilk test. Homogeneity was analyzed using Levene's test. The comparison between the parameters used was analyzed using the Two-way ANOVA test. The T test was applied to data relating to viability and lesion area. For LED photobiomodulation, only the 630 nm wavelength obtained a significant result in 24, 48 and 72 h (p = 0,027; p = 0,024; p = 0,009). The results related to the in vitro wound closure test indicate that both photobiomodulation with laser and LED demonstrated significant results considering the time it takes to approach the edges (p < 0.05). Considering the in vitro experimental conditions of the study, it is possible to conclude that the physical parameters of photobiomodulation, such as energy and wavelength, with laser or LED in mesenchymal stem cells, can play a potential role in cell viability and wound closure.


Assuntos
Sobrevivência Celular , Terapia com Luz de Baixa Intensidade , Células-Tronco Mesenquimais , Cicatrização , Células-Tronco Mesenquimais/efeitos da radiação , Humanos , Sobrevivência Celular/efeitos da radiação , Terapia com Luz de Baixa Intensidade/métodos , Cicatrização/efeitos da radiação , Células Cultivadas , Lasers Semicondutores/uso terapêutico , Proliferação de Células/efeitos da radiação , Adipócitos/efeitos da radiação , Adipócitos/citologia
3.
Lasers Med Sci ; 39(1): 171, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38965082

RESUMO

To evaluate the effects of red and infrared wavelengths, separately and combined, on the inflammatory process and collagen deposition in muscle damage caused by B. leucurus venom. 112 mice were inoculated with diluted venom (0.6mg/kg) in the gastrocnemius muscle. The animals were divided into four groups: one control (CG) and three treatments, namely: 1) red laser (λ=660 nm) (RG), 2) infrared laser (λ=808 nm) (IG) and 3) red laser (λ=660 nm) + infrared (λ=808 nm) (RIG). Each group was subdivided into four subgroups, according to the duration of treatment application (applications every 24 hours over evaluation times of up to 144 hours). A diode laser was used (0.1 W, CW, 1J/point, ED: 10 J/cm2). Both wavelengths reduced the intensity of inflammation and the combination between them significantly intensified the anti-inflammatory response. Photobiomodulation also changed the type of inflammatory infiltrate observed and RIG had the highest percentage of mononuclear cells in relation to the other groups. Hemorrhage intensity was significantly lower in treated animals and RIG had the highest number of individuals in which this variable was classified as mild. As for collagen deposition, there was a significant increase in RG in relation to CG, in RIG in relation to CG and in RIG in relation to IG. Photobiomodulation proved to be effective in the treatment of inflammation and hemorrhage caused by B. leucurus venom and stimulated collagen deposition. Better results were obtained with the combined wavelengths.


Assuntos
Bothrops , Colágeno , Venenos de Crotalídeos , Hemorragia , Inflamação , Terapia com Luz de Baixa Intensidade , Músculo Esquelético , Animais , Camundongos , Terapia com Luz de Baixa Intensidade/métodos , Músculo Esquelético/efeitos da radiação , Músculo Esquelético/efeitos dos fármacos , Hemorragia/patologia , Colágeno/metabolismo , Colágeno/análise , Venenos de Crotalídeos/toxicidade , Raios Infravermelhos , Masculino , Lasers Semicondutores/uso terapêutico , Mordeduras de Serpentes/radioterapia
4.
Braz Oral Res ; 38: e045, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38922205

RESUMO

This study aimed to evaluate the influence of the Er,Cr:YSGG irradiation and 980-nm diode lasers on the surface roughness (SR) and volume loss (VL) of dentin subjected to cariogenic challenge. Subsequently, 130 specimens of bovine dentin were divided into the following 13 groups: NT: no treatment; FG: fluoride gel; FV: fluoride varnish; Di: 980-nm diode; Di + FG; Di + FV; FG + D; FV + Di; Er: Er,Cr:YSGG; Er + FG; Er + FV; FG + Er and FV + Er. Er,Cr:YSGG laser parameters were as follows: 0.25 W; 5.0 Hz; 4.46 J/cm2 without water and 55% air. Furthermore, the 980-nm diode laser parameters were 2.0 W; 2.0 Hz; 21.41 J/cm2. The samples from each group were subjected to pH cycling. A confocal laser scanning microscope was used to evaluate SR and VL. Difference between the volume of the reference and treated areas + DES/RE was used to determine SR and VL. The mean values of the different groups were subjected to analysis of variance and Tukey's post-hoc test. The VL values were analyzed using the Kruskal-Wallis and Dunn post-hoc test (p < 0.05). The SR of the reference area did not show a statistically significant 1807-3107-bor-38-e025treatment and cariogenic challenge (p > 0.05). Moreover, VL in the FV + Di and FV + Er groups showed a statistically significant difference compared with areas submitted to different types of treatment and cariogenic challenge (p > 0.05). Er,Cr:YSGG and 980-nm diode lasers associated with fluoride varnishes decreased dentin VL in bovine teeth submitted to cariogenic challenge.


Assuntos
Dentina , Lasers Semicondutores , Lasers de Estado Sólido , Microscopia Confocal , Propriedades de Superfície , Bovinos , Animais , Lasers Semicondutores/uso terapêutico , Dentina/efeitos dos fármacos , Dentina/efeitos da radiação , Lasers de Estado Sólido/uso terapêutico , Reprodutibilidade dos Testes , Cárie Dentária/terapia , Análise de Variância , Valores de Referência , Fluoretos Tópicos , Cariostáticos/química , Fatores de Tempo , Concentração de Íons de Hidrogênio
5.
Sci Rep ; 14(1): 11457, 2024 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769365

RESUMO

To compare two different wavelengths of the surgical contact diode laser (CDL) for producing a posterior laryngofissure in in-vivo pigs. Anesthetized pigs underwent a tracheostomy and an anterior laryngofissure through a cervicotomy. They were randomly selected for the CDL wavelength and Power, according to the peak of Power set at device (980nm wavelength: Ppeak power of 10 W, 15 W, and 20 W, or 1470 nm wavelength: Ppeak 3 W, 5 W, 7 W, 10 W). At the end of the experiment, the laryngotracheal specimen was extracted and sent for histology and morphometry measurements (incision size, depth, area, and lateral thermal damage). Hemodynamic data and arterial blood gases were recorded during the incisions. Statistical analysis of the comparisons between the parameters and groups had a level of significance of p < 0.05. Twenty-six pigs were divided into CDL 980 nm (n = 11) and 1470 nm (n = 15). There was a greater incision area at the thyroid level in the 980 nm CDL and a wider incision at the trachea level, with a larger distance between mucosa borders. There were no significant differences in the area of lateral thermal damage between the two groups and neither difference among the power levels tested. Both wavelengths tested showed similar results in the various combinations of power levels without significant differences in the lateral thermal damage. The posterior laryngofissure incision can be performed by either of the wavelengths at low and medium power levels without great difference on lateral thermal damage.


Assuntos
Laringe , Lasers Semicondutores , Animais , Suínos , Laringe/cirurgia , Terapia a Laser/métodos , Traqueia/cirurgia
6.
Photobiomodul Photomed Laser Surg ; 42(6): 422-427, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38717840

RESUMO

Objective: To present a case report of maxillary lateral incisor root regeneration after severe root resorption, treated with photobiomodulation (PBM). Background: Impacted maxillary canines often come with the risk of maxillary lateral incisor root resorption, which is widely recognized as the predominant adverse effect in these situations. This progressive process of root resorption is currently irreversible, with no known way to reverse it. Materials and methods: A male patient was 14 years old. Radiographically it was observed that canine 23 is impacting against the root of 22 producing signs of root resorption and having a less than 1:1 crown-to-root ratio with mobility grade 1. From the beginning of the treatment, PBM-assisted orthodontics was proposed. To address the patient's dental concerns, the treatment plan outlined the extraction of the deciduous upper left canine tooth leaving the lateral as long as possible in the mouth. During each appointment, PBM was applied with a diode laser. The wavelength was 810 nm, Ap = 0.2 W, 4.4 J, 22 sec every 21 days, 13 applications in total (57.2J), with a 400 µm inactive surgical tip, in a scanning movement, 1 mm from the mucosa while moving following the vestibular surface of the upper left lateral and canine roots. Results: After 12 months, the 22 had root neoformation and complete closure of the apex with vitality. Conclusions: PBM with an 810 nm diode laser in this clinical case promoted root regeneration of an upper lateral incisor, with severe root resorption, owing to an impacted maxillary canine while still vital.


Assuntos
Dente Canino , Incisivo , Terapia com Luz de Baixa Intensidade , Reabsorção da Raiz , Dente Impactado , Humanos , Masculino , Reabsorção da Raiz/etiologia , Adolescente , Regeneração/efeitos da radiação , Maxila , Raiz Dentária/efeitos da radiação , Lasers Semicondutores/uso terapêutico
7.
Braz Oral Res ; 38: e025, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38597545

RESUMO

Treatment of oral vascular anomalies (OVA) has focused on minimally invasive techniques rather than radical surgery. We investigated the efficacy and safety of diode laser using the photocoagulation technique in the management of OVA. Forty-seven subjects with OVA were treated with forced dehydration with induced photocoagulation (FDIP) using diode laser (808 nm/4.5 W). This series consisted mostly of male (63.8%) and non-white (63.8%) patients with a mean age of 57.4 years. Varices (91.5%), venous malformations (6.4%), and hemangiomas (2.1%) with a mean size of 7.1 (±4.9) mm were the conditions treated. OVA presented as a nodular lesion (63.8%) involving mainly the lower lip (46.8%). Pulsed laser mode was used as standard and the number of applications varied from one to four sessions, with the majority requiring only one (83%) FDIP session. Kaplan-Meier analysis revealed that complete clinical healing can occur on the 15th day (n=9/29.5%), followed by the 20th (n=6/45.5%), and 30th (n=7/70.5%) days. Postoperative edema was observed in 31 (66%) patients, and recurrence of the lesion occurred in two (4.2%). Based on the data on complete clinical healing, minimal patient discomfort, and satisfactory esthetic results, we can confirm that FDIP by diode laser is a promising candidate for the safe and efficacious treatment of OVA.


Assuntos
Lasers Semicondutores , Lábio , Humanos , Masculino , Pessoa de Meia-Idade , Lasers Semicondutores/uso terapêutico , Lábio/cirurgia , Lábio/irrigação sanguínea , Resultado do Tratamento , Cicatrização
8.
J Appl Oral Sci ; 32: e20230419, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38655987

RESUMO

OBJECTIVE: This study compared a dual-wavelength diode laser and an Er, Cr:YSGG laser in oral soft tissue incisions to determine the most effective and safest laser system at the histopathological level. METHODOLOGY: The (810 and 980 nm) dual-wavelength diode laser was used at 1.5 W and 2.5 W (CW) power settings, and the (2780 nm) Er, Cr:YSGG laser was used at 2.5 W and 3.5 W (PW) power settings. Both laser systems were used to incise the tissues of freshly dissected sheep tongue pieces to obtain the following histopathological criteria: epithelial tissue changes, connective tissue changes, and lateral thermal damage extent by optical microscopy. RESULTS: The epithelial and connective tissue damage scores were significantly higher in the dual-wavelength diode laser groups than in the Er, Cr:YSGG laser groups (P<0.001), and there was a significant difference between some groups. The extent of lateral thermal damage was also significantly higher in the diode laser groups than in the Er, Cr: YSGG laser groups (P<0.001), and there was a significant difference between groups. Group 2 (2.5 W) of the diode laser was the highest for all three criteria, while group 3 (2.5 W) of the Er, Cr:YSGG laser was the lowest. CONCLUSION: The Er, Cr:YSGG laser with an output power of 2.5 W is, histologically, the most effective and safest laser for oral soft tissue incision. The dual-wavelength diode laser causes more damage than the Er, Cr:YSGG laser, but it can be used with a low output power and 1 mm safety distance in excisional biopsy.


Assuntos
Lasers Semicondutores , Lasers de Estado Sólido , Margens de Excisão , Língua , Animais , Lasers Semicondutores/uso terapêutico , Lasers de Estado Sólido/uso terapêutico , Língua/cirurgia , Língua/patologia , Reprodutibilidade dos Testes , Ovinos , Tecido Conjuntivo/patologia , Epitélio/patologia , Valores de Referência , Procedimentos Cirúrgicos Bucais/métodos , Mucosa Bucal/patologia , Mucosa Bucal/cirurgia , Estatísticas não Paramétricas , Terapia a Laser/métodos , Terapia a Laser/instrumentação
9.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38656028

RESUMO

PURPOSE: The purpose of this study is to assess the long-term outcomes of modified transcanalicular diode laser dacryocystorhinostomy in a large cohort of patients affected by primary acquired nasolacrimal duct obstruction. METHODS: This study, conducted from January 17 to June 2022, encompassed 141 patients (159 procedures) who underwent modified transcanalicular diode laser dacryocystorhinostomy (MT-DCR). The procedure employed an 810-nm diode laser. Patients were monitored for at least a year after the intervention. Anatomical success was determined by ostium patency upon irrigation, while functional success referred to epiphora resolution. Parameters studied included patient demographics, procedure duration, complications, and both anatomical and functional success. Statistical analysis was performed using the Statistical Package for the Social Sciences software, with results considered significant at a 95% confidence interval (p≤0.05). RESULTS: A total of 159 lacrimal drainage systems (141 patients: 112 women and 29 men) were included in this study. Among them, 18 underwent bilateral procedures. The average patient age was 58 years (range: 34-91 years), and the average surgical duration was 24 minutes (range: 18-35 minutes). One year after the surgery, MT-DCR exhibited anatomical and functional success rates of 84.9% (135/159) and 83% (132/159), respectively. CONCLUSION: MT-DCR achieved an anatomical success rate of 84.9%, reflecting an excellent outcome. However, further extensive studies with larger sample sizes and longer follow-up periods are necessary to substantiate these findings.


Assuntos
Dacriocistorinostomia , Obstrução dos Ductos Lacrimais , Lasers Semicondutores , Humanos , Dacriocistorinostomia/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Resultado do Tratamento , Lasers Semicondutores/uso terapêutico , Idoso de 80 Anos ou mais , Fatores de Tempo , Ducto Nasolacrimal/cirurgia , Duração da Cirurgia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA