Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 695
Filtrar
1.
J Dent ; 149: 105267, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39067647

RESUMO

AIM: The positive impact of implant interventions on dental patient-reported outcomes is an essential parameter of treatment effectiveness. This study assessed the 2-year changes in patient satisfaction and oral health-related quality of life (OHRQoL) of edentulous patients treated with a four mini implant mandibular overdenture (IOD) METHODS: The study was planned as a 2 × 2 factorial randomized clinical trial that tested two surgical approaches (flapped or flapless) and two loading protocols (immediate and delayed) using a titanium-zirconium mini implant (Straumann Mini Implant System®) and a PEEK retentive system (Straumann® Optiloc® Retentive System). Outcome measures (OHIP-Edent scores and the McGill Denture Satisfaction questionnaire) were assessed before treatment and at the 3-, 6-, 12-, and 24-month follow-ups. The Friedman test and multiple regression using Generalized Estimating Equations (GEE) were used for data analysis, considering the per-protocol (PP) and intention-to-treat (ITT) approaches RESULTS: Seventy-four patients were randomized to the study groups. No implant failure occurred during the study period. Marked improvement in all post-treatment periods compared to baseline were observed for the two outcomes. No significant effect of patient's gender, age, and surgical protocol on the study outcomes. The effect of treatment provision was significant for the two outcomes in the PP and ITT approaches (p < 0.001). A barely significant positive effect of the immediate loading was observed for OHIP-Edent in the PP approach (p = 0.020) CONCLUSION: IOD treatment significantly improved patient-reported outcomes measures, with sustained benefits over the two years of overdenture use, and can be considered a promising treatment option in for the edentulous mandible.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Arcada Edêntula , Mandíbula , Medidas de Resultados Relatados pelo Paciente , Satisfação do Paciente , Qualidade de Vida , Titânio , Zircônio , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Mandíbula/cirurgia , Arcada Edêntula/reabilitação , Arcada Edêntula/cirurgia , Retenção de Dentadura , Resultado do Tratamento , Prótese Total Inferior , Planejamento de Dentadura , Saúde Bucal , Carga Imediata em Implante Dentário
2.
J Dent ; 149: 105266, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39067651

RESUMO

OBJECTIVE: This 2-year prospective study reports the incidence of prosthetic complications and maintenance events after treatment with mandibular overdenture retained by four mini implants opposed to a maxillary denture. METHODS: Implant intervention included flapless or flapped surgery combined with immediate or delayed loading, as part of a randomized clinical trial. Four one-piece titanium-zirconium mini-implants (Straumann Mini Implant System) were inserted, and the retentive PEEK elements (Optiloc) were incorporated into the overdenture using chairside procedures. Prosthodontic complications and maintenance events were recorded over a 2-year follow-up, and the final outcome was defined according to standardized criteria. Data analysis included descriptive statistics, incidence and incidence density rates, and Kaplan-Meier survival. RESULTS: 73 out of 74 patients (64.9 % female), mean age of 64 (SD=8.2) years, completed the study follow-up (one withdrew after 9 months). Implant survival was 100 %. A total of 163 prosthodontic events occurred in 53 patients (72.6 %), and 20 patients had no clinical complaints or maintenance needs. The most common procedures were adjustment/repair of the overdenture base (47.0 %), replacement of retentive inserts (19.8 %), and laboratory relining (12.9 %). A high prosthodontic success rate was achieved (93.2 %), and all patients presented serviceable overdentures and continuous use after the resolution of prosthodontic complications. The incidences of matrix replacement and laboratory relines were low in the first year, while denture base adjustments were common within the first year, especially in the first 6 months. CONCLUSION: The mini implant system showed high prosthodontic success rates. Minor adjustments/repairs during the initial follow-up were common. Relines and matrix replacements tend to occur after one year of overdenture use, and matrix replacements may occur as a consequence of the need for relining.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Retenção de Dentadura , Revestimento de Dentadura , Titânio , Zircônio , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Seguimentos , Estudos Prospectivos , Retenção de Dentadura/instrumentação , Idoso , Resultado do Tratamento , Mandíbula/cirurgia , Planejamento de Dentadura , Reparação em Dentadura , Prótese Total Inferior
3.
J. oral res. (Impresa) ; 13(1): 136-149, mayo 29, 2024. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1563412

RESUMO

Background: Denture adhesives are alternatives used to improve retention, stability, comfort and satisfaction in patients with complete dentures. Evidence on the effectiveness of denture adhesives on resorbed mandibular ridges is scarce. Among the many commercially available denture adhesives, the ideal material for the severely resorbed mandibular ridge remains in dispute. Objective: The aim of this study was to evaluate the effectiveness of different quantities of four commercially available denture adhesives on the retention of mandibular complete dentures in severely resorbed ridges. Materials and Methods: A resorbed edentulous mandibular ridge model was manufactured in acrylic resin. A denture base was made and three loops were attached to it. Four commercially available denture adhesives (Fixodent, Perlie White, Fiftydent and Polident) were tested in amounts of 0.2 g, 0.4 g, 0.6 g, 0.8 g and 1.0 g. The acrylic resin model was evenly moistened with 1 ml of water and a weighted amount of adhesive material was applied to the denture base. The universal testing machine engaged the loops fixed on the denture base and applied the vertical displacement force. The maximum vertical displacement force values were recorded for each denture adhesive material at different amounts. Statistical calculation was performed using Kruskal Wallis with Bonferroni post hoc correction. Results: Statistically significant differences were observed in the mean values of the vertical displacement force for adhesive amounts of 0.2 g, 0.4 g, 0.6 g and 1.0 g (p<0.05) between the four adhesive materials tested. Statistically significant differences were observed when four denture adhesives were compared to each other in different amounts (p<0.05). Statistically significant differences were observed between different amounts for each of four denture adhesives (p<0.05). Conclusions: Among the four materials tested, Polident showed greater effectiveness at 0.6 g and 0.8 g, Fittydent at 0.6 g, 0.8 g and 1 g, Fixodent at 0.4 g and 0.6 g and Perlie White at 1 g and 0.8g quantity to resist vertical displacement. forces on the severely resorbed mandibular crest. Using an appropriate amount of denture adhesive allows for proper retention of the denture; Replacement of this adhesive is necessary once a day.


Introducción: Los adhesivos para prótesis dentales son alternativas utilizadas para mejorar la retención, la estabilidad, la comodidad y la satisfacción en los pacientes con prótesis completas. La evidencia sobre la efectividad de los adhesivos para prótesis dentales en los rebordes mandibulares reabsorbidos es escasa. Entre los muchos adhesivos para prótesis dentales disponibles comercialmente, sigue estando en disputa cuál es el material ideal para el reborde mandibular severamente reabsorbido. Objetivo: El objetivo de este estudio fue evaluar la efectividad de diferentes cantidades de cuatro adhesivos para prótesis dentales disponibles comercialmente sobre la retención de prótesis dentales completas mandibulares en reborde mandibular reabsorbido severamente. Materiales y Métodos: Se fabricó un modelo de reborde mandibular edéntulo reabsorbido en resina acrílica. Se hizo una base para la prótesis y se le colocaron tres bucles. Se probaron cuatro adhesivos para dentaduras postizas disponibles comercialmente (Fixodent, Perlie White, Fiftydent y Polident) en cantidades de 0,2 g, 0,4 g, 0,6 g, 0,8 g y 1,0 g. El modelo de resina acrílica se humedeció uniformemente con 1 ml de agua y se aplicó la cantidad correspondiente de material adhesivo sobre la base de la dentadura. La máquina de prueba universal enganchó los bucles fijados en la base de la dentadura postiza y aplicó la fuerza de desplazamiento vertical. Se registraron los valores máximos de fuerza de desplazamiento vertical para cada material adhesivo para dentaduras postizas en diferentes cantidades. El cálculo estadístico se realizó utilizando Kruskal Wallis con corrección post hoc de Bonferroni. Resultado: Se observaron diferencias estadísticamente significativas en los valores medios de la fuerza de desplazamiento vertical para cantidades de 0,2 g, 0,4 g, 0,6 g y 1,0 g (p<0,05) entre los cuatro materiales adhesivos para prótesis dentales probados. Se observaron diferencias estadísticamente significativas cuando se compararon cuatro adhesivos para prótesis dentales entre sí en diferentes cantidades (p<0,05). Se observaron diferencias estadísticamente significativas entre diferentes cantidades en los cuatro adhesivos para prótesis (p<0,05). Conclusión: De los cuatro materiales probados, Polident mostró mayor efectividad a 0,6 g y 0,8 g, Fittydent a 0,6 g, 0,8 g y 1 g, Fixodent a 0,4 g y 0,6 g y Perlie White a 1 g y 0,8 g para resistir fuerzas de desplazamiento vertical en la cresta mandibular severamente reabsorbida. El uso de una cantidad adecuada de adhesivo para dentaduras postizas permite una retención adecuada de la dentadura postiza; El reemplazo de este adhesivo es necesario una vez al día.


Assuntos
Humanos , Adesivos/uso terapêutico , Retenção de Dentadura/métodos , Planejamento de Dentadura , Prótese Dentária/métodos , Modelos Dentários , Prótese Total , Mandíbula/patologia
4.
Clin Oral Investig ; 28(6): 320, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38750145

RESUMO

OBJECTIVES: The purpose of this scoping review was to identify different methods employed for recording the maxillomandibular relationship (MMR) for computer-aided designed and manufactured (CAD-CAM) complete dentures (CDs). MATERIALS AND METHODS: This scoping review followed the PRISMA-ScR guidelines and was developed according to Arksey and O'Malley and The Joanna Briggs Institute protocol. The methods were registered on the Open Science Framework (< osf.io/rf4xm> ). The focus question was: "What are the different techniques for recording the maxillomandibular relationship in the digital workflow used in CECDs?" Two investigators searched 3 online databases [MEDLINE (PubMed), Scopus, and Science Direct] independently. The inclusion criteria were clinical studies and reviews that assessed techniques for recording MMR using digital workflow for manufacturing of CECDs. A descriptive analysis was performed considering the study design, manufacturing system, clinical steps, and tools for the determination of MMR, and the difficulty level of procedures. RESULTS: 4779 articles were identified in the electronic search and 10 studies were included for data analysis. The review identified 4 commercially available CAD-CAM denture systems and 3 innovative methods suitable for abbreviating the number of appointments (2 to 4 visits). The trial denture is inherent to the procedure for the Baltic System and 3 innovative techniques. Three techniques (2 innovative and WholeYouNexteeth) demonstrated lower difficulty levels for performing the clinical procedures, regardless of the professional skills. CONCLUSIONS: The commercially available and innovative techniques for the recording of MMR may provide predictability of the treatment. The techniques are effective, however, rely on the learning curve and the patient's clinical condition. CLINICAL RELEVANCE: Recording of the maxillomandibular relationship is paramount for the manufacturing and functionality of complete dentures. Clinicians should be aware of the different tools and techniques described for registering the jaw relationship.


Assuntos
Desenho Assistido por Computador , Planejamento de Dentadura , Prótese Total , Humanos , Planejamento de Dentadura/métodos , Registro da Relação Maxilomandibular/métodos
5.
J Prosthet Dent ; 131(6): 1252.e1-1252.e10, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38553302

RESUMO

STATEMENT OF PROBLEM: The difference in chemical composition between denture base resin and denture teeth requires the development of bonding protocols that increase the union between the materials. PURPOSE: The purpose of this in vitro study was to evaluate the impact of different bonding protocols on the bond between heat-polymerized and 3-dimensionally (3D) printed acrylic resin denture bases and acrylic resin prefabricated and 3D printed artificial teeth. MATERIAL AND METHODS: Four types of artificial teeth were evaluated: prefabricated acrylic resin (VITA MFT) and 3D printed (Cosmos TEMP, PRIZMA 3D Bio Denture, and PrintaX AA Temp) bonded to 20×24-mm cylinders of heat-polymerized (VipiWave) and 3D printed (Cosmos Denture, PRIZMA 3D Bio Denture, and PrintaX BB Base) denture bases. Three bonding protocols were tested (n=20): mechanical retention with perforation + monomer (PT1), mechanical retention with perforation + airborne-particle abrasion with 50-µm aluminum oxide + monomer (PT2), and mechanical retention with perforation + Palabond (PT3). Half of the specimens in each group received 10 000 thermocycles and were then subjected to the bonding test at a crosshead speed of 1 mm/minute. The failure type was analyzed and scanning electron micrographs made. Additionally, surface roughness (Ra) and wettability (degree) were analyzed (n=15). ANOVA was used to evaluate the effect of the bonding protocol, and the Student t test was applied to compare the experimental groups with the control (α=.05). For type of failure, a descriptive analysis was carried out using absolute and relative frequency. The Kruskal-Wallis test was used to evaluate the surface changes (α=.05). RESULTS: Among the protocols, PT3 with in Yller and PT2 with Prizma had the highest bond strengths of the heat-polymerized denture base and 3D printed teeth (P<.05). When comparing the experimental groups with the control, PT3 and PT2 had greater union with the 3D printed denture base + 3D printed teeth (in Yller), with no difference from the heat-polymerized denture base + prefabricated teeth in acrylic resin. The treatment of the 3D printed tooth surfaces affected the surface roughness of Prizma (P<.001) and wettability (P<.001). CONCLUSIONS: To increase the bond between Yller 3D printed denture base + 3D printed teeth, a bonding protocol including mechanical retention with perforation + Palabond or mechanical retention with perforation + airborne-particle abrasion with aluminum oxide + monomer is indicated. For the other materials tested, further bonding protocols need to be investigated.


Assuntos
Resinas Acrílicas , Colagem Dentária , Bases de Dentadura , Impressão Tridimensional , Dente Artificial , Resinas Acrílicas/química , Colagem Dentária/métodos , Técnicas In Vitro , Teste de Materiais , Propriedades de Superfície , Humanos , Materiais Dentários/química , Planejamento de Dentadura
6.
Spec Care Dentist ; 44(1): 124-129, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37013961

RESUMO

OBJECTIVE: To present clinical strategies for prosthetic rehabilitation with complete dentures (CDs) of a Parkinson's disease patient. CASE REPORT: An 82-year-old patient sought the Department of Dentistry at UFRN, reporting retention dissatisfaction and hamper to the mandibular CD adaptation. Patient-reported a dry mouth sensation, and exhibited disordered mandibular movements, tremors, and resorbed mandibular ridge. Aiming retention and stability, double molding with zinc enolic oxide impression paste, neutral zone technique, and non-anatomic teeth were proposed as clinical strategies. At delivery, identification and relief in the supercompression areas were performed to facilitate the acceptance and use of the new dentures. CONCLUSION: The strategies promoted patient satisfaction regarding retention, stability, and comfort. This treatment may be considered for the rehabilitation of Parkinson's disease patients, favoring the adaptation process.


Assuntos
Doença de Parkinson , Humanos , Idoso de 80 Anos ou mais , Doença de Parkinson/complicações , Planejamento de Dentadura/métodos , Retenção de Dentadura/métodos , Prótese Total , Satisfação do Paciente
7.
Int. j. odontostomatol. (Print) ; 17(2): 186-195, jun. 2023. ilus
Artigo em Espanhol | LILACS | ID: biblio-1440357

RESUMO

Establecer un protocolo de cirugía guiada estática con técnicas referenciales para ser realizado de manera predecible, repetible y simple, en todos los tipos de casos. El protocolo abreviado guiado digital para cirugía guiada estática para implantes se centra en diseñar computacionalmente una guía quirúrgica que se apoye en el tejido remanente del paciente, siendo un protocolo digital versátil para la cirugía y rehabilitación implanto protésica, basada en registros clínicos, principalmente la línea de la sonrisa y la captación de ésta en tomografía de haz cónico (CBCT), además de establecer dimensión vertical oclusal (DVO). Logrando así, planificación de implantes hasta la inserción inmediata de la prótesis temporal. Se ejemplifica el trabajo con 2 casos clínicos. Se establece un protocolo con la intención de que pueda ser realizado en pacientes desdentados parciales (Técnica de Registro Silicona) o totales (Técnica de Marcadores Tisulares en prótesis), definiendo un flujo de trabajo tridimensional, digital y optimizado, con un consecuente ahorro de tiempo clínico. Como principio del protocolo de cirugía guiada es lograr el objetivo quirúrgico - protésico deseado con alta precisión. La cirugía y rehabilitación de implantes de manera convencional es altamente dependiente del operador por lo que la alternativa de cirugía guiada de manera estática es una herramienta más para mejorar el pronóstico del paciente. Se establece un protocolo digital simple y efectivo, de cirugía guiada, para la rehabilitación implanto protésica basada en la línea de la sonrisa, tomografía de haz cónico (CBCT), dimensión vertical oclusal (DVO). Protocolo predecible y que optimiza los tiempos clínicos, logrando una rehabilitación protésica inmediata acorde e individualizada para cada paciente.


Establish a static guided surgery protocol with referential techniques to be performed in a predictable, repeatable and simple way, in all types of cases. The abbreviated digital guided protocol for static guided surgery for implants focuses on computationally designing a surgical guide that rests on the patient's remaining tissue, being a versatile digital protocol for prosthetic implant surgery and rehabilitation, based on clinical records, mainly the line of the smile and its uptake in cone beam tomography (CBCT), in addition to establishing occlusal vertical dimension (OVD). Thus achieving implant planning until the immediate insertion of the temporary prosthesis. The work is exemplified with 2 clinical cases. A protocol is established with the intention that it can be carried out in partially edentulous patients (Silicone Registration Technique) or total (Tissue Marker Technique in prostheses), defining a three-dimensional, digital and optimized workflow, with a consequent saving of time. clinical. As a principle of the guided surgery protocol, it is to achieve the desired surgical-prosthetic objective with high precision. Conventional implant surgery and rehabilitation is highly dependent on the operator, so the alternative of statically guided surgery is one more tool to improve the patient's prognosis. A simple and effective digital protocol for guided surgery is established for prosthetic implant rehabilitation based on the smile line, cone beam tomography (CBCT), and occlusal vertical dimension (OVD). Predictable protocol that optimizes clinical times, achieving an immediate and individualized prosthetic rehabilitation for each patient.


Assuntos
Humanos , Masculino , Feminino , Idoso , Implantes Dentários , Protocolos Clínicos , Cirurgia Assistida por Computador/métodos , Sorriso , Planejamento de Dentadura , Tomografia Computadorizada de Feixe Cônico
8.
J Prosthet Dent ; 130(3): 341-350, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34991859

RESUMO

STATEMENT OF PROBLEM: The complete denture occlusal scheme may influence clinical performance and patient satisfaction. However, a consensus on which occlusal scheme should be used for complete denture users is lacking. As a result, many dentists choose the scheme based on their preferences and clinical experience. PURPOSE: The purpose of this review was to assess the methodological quality and summarize the scientific evidence from secondary studies about the influence of occlusal schemes on the clinical performance of and patient satisfaction with complete dentures. MATERIAL AND METHODS: Ten sources were surveyed according to the patient, intervention, comparison, outcome (PICO) strategy. Systematic reviews that evaluated the clinical performance and patient satisfaction (O) of rehabilitated edentulous patients with conventional complete dentures (P) under different occlusal schemes (I/C) were included. Methodological quality was assessed by using A MeaSurement Tool to Assess systematic Reviews (AMSTAR) 2 tool by 2 authors independently. The effect of each occlusal scheme in comparison with others was summarized and classified as positive, neutral, negative, or inconclusive based on the conclusions of the systematic review concerning clinical performance and patient satisfaction outcomes. RESULTS: The search led to the inclusion of 10 systematic reviews. Seven were classified as of critically low, 2 as low, and 1 as moderate methodological quality. The following occlusal designs were included and analyzed: bilateral balanced occlusion, lingualized occlusion, canine guidance, group function, and monoplane occlusion. Bilateral balanced occlusion and canine guidance obtained satisfactory results for both outcomes. Lingualized occlusion showed a trend toward better results than other occlusal schemes for normal and resorbed ridges. Group function presented mainly inconclusive results, and monoplane occlusion did not deliver satisfactory outcomes. CONCLUSIONS: The present overview concluded that occlusal schemes might interfere with the clinical performance of and patient satisfaction with complete dentures. Lingualized, bilateral balanced, and canine guidance are preferred compared with monoplane occlusion, but lingualized occlusion tends to show better results in some reviews. However, the results should be carefully considered because of the low quality of the systematic reviews included.


Assuntos
Planejamento de Dentadura , Satisfação do Paciente , Humanos , Revisões Sistemáticas como Assunto , Prótese Total , Oclusão Dentária , Oclusão Dentária Balanceada , Mastigação
9.
J Prosthet Dent ; 129(4): 547-553, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34332774

RESUMO

STATEMENT OF PROBLEM: The introduction of computer-aided design and computer-aided manufacturing (CAD-CAM) technology for complete denture fabrication may have improved clinical outcomes compared with conventional techniques. However, systematic reviews comparing these techniques are lacking. PURPOSE: The purpose of this systematic review was to identify, compare, and synthesize the outcomes of published clinical studies related to complete denture fabrication, with respect to the differences between CAD-CAM technology and conventional techniques. MATERIAL AND METHODS: A comprehensive search of studies published up to March 16, 2020, was conducted by using the PubMed/MEDLINE, Web of Science, Cochrane Library, SciELO, and Embase databases according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement criteria and was registered in the International Prospective Register of Systematic Reviews (PROSPERO ID 42020202614). The population, intervention, comparison, and outcome (PICO) question was: Do CAD-CAM complete dentures have a similar functional performance to those fabricated by conventional techniques? The quality of publications was appraised by using the Critical Appraisal Skills Program (CASP) checklists. RESULTS: Of the 1232 titles, 6 articles were selected. The studies reported better retention of digitally manufactured complete dentures without denture adhesives than that of conventional complete dentures with or without denture adhesives. Other studies reported that dentures manufactured with digital systems were better adapted to tissue surfaces, required less clinical time, were lower in cost, and provided better experience and satisfaction to patients. CONCLUSIONS: The assessment of CAD-CAM planning and manufacturing through clinical studies is ongoing. However, preliminary results indicate better clinical performance and lower overall costs of digital complete dentures than conventional dentures.


Assuntos
Planejamento de Dentadura , Prótese Total , Humanos , Planejamento de Dentadura/métodos , Desenho Assistido por Computador , Tecnologia
10.
Geriatr., Gerontol. Aging (Online) ; 17: 1-4, 2023. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1428360

RESUMO

BACKGROUND AND OBJECTIVE: Parkinson's disease is a neurological disorder that affects 1% of individuals aged 60 years and older. The associated symptoms can impose limitations on the available dental treatment options. CASE DESCRIPTION: This case report follows the CARE guidelines and presents an adapted and simplified technique to fabricate complete dentures for a 74-year-old male edentulous patient with Parkinson's disease. This modified technique enabled the fabrication of complete dentures in 4 clinical sessions of approximately 40 minutes. The first session involved manufacturing a preliminary impression with fast-setting alginate. The base plates and occlusal rims were then adjusted for artificial teeth arrangement during the second session. The final prosthesis was completed in the third session, which involved a teeth try-in and fabrication of a functional impression with low-melting thermoplastic material and polyether. Finally, denture installation was performed in the fourth session and follow-up consisted of 3 weekly sessions. DISCUSSION: Considering that the treatment provided satisfactory aesthetics and function, mastication and socialization benefits, and improved the self-esteem and well-being of the older patient with Parkinson's disease, the authors suggest this adapted and simplified technique for fabricating complete dentures. (AU)


JUSTIFICATIVA E OBJETIVO: A doença de Parkinson é uma desordem neurológica que afeta 1% dos indivíduos com 60 anos ou mais. Os sintomas associados podem impor limitações nas opções de tratamento odontológico disponíveis. DESCRIÇÃO DO CASO: Este relato de caso segue o protocolo CARE e apresenta uma adaptação da técnica simplificada para confecção de novas próteses totais, para um paciente edêntulo, do sexo masculino, de 74 anos com doença de Parkinson. Essa técnica modificada possibilita a confecção de próteses totais em quatro sessões clínicas de aproximadamente 40 minutos. A primeira sessão envolveu uma moldagem preliminar com alginato de presa rápida. As placas articulares com rodetes de cera foram ajustadas para montagem dos dentes artificiais durante a segunda sessão. A prótese definitiva foi concluída na terceira sessão, que envolveu a prova dos dentes e moldagem funcional com material termoplástico de baixa fusão e poliéter. Por fim, a instalação da prótese foi realizada na quarta sessão e o acompanhamento consistiu em três sessões semanais. DISCUSSÃO: Considerando que o tratamento proporcionou estética e função satisfatórias, benefícios mastigatórios e de socialização, melhora da autoestima e bem-estar do idoso com doença de Parkinson, os autores sugerem o uso da adaptação da técnica simplificada para confecção de prótese total. (AU)


Assuntos
Humanos , Masculino , Idoso , Doença de Parkinson , Planejamento de Dentadura/métodos , Boca Edêntula/reabilitação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA