Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Clin Transl Oncol ; 25(5): 1287-1296, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36482229

RESUMO

PURPOSE: To investigate development of radiation pneumonitis (RP) in relation to pulmonary function, dosimetric factors, and transforming growth factor beta-1 (TGFß1) expression in irradiated breast cancer patients. METHODS: A total of 49 breast cancer patients who received post-operative radiotherapy (RT) were evaluated in terms of pulmonary function tests (PFTs), quality of life (QoL), development of RP, dosimetric factors, cytokine levels, and lung high-resolution computed tomography (HRCT) before and after RT. ROC analysis was performed for performance of dosimetric factors in predicting RP, while frequencies of single nucleotide polymorphisms (SNPs) genotyped for TGFß1 (rs11466345 and rs1800470) were also evaluated. RESULTS: All cases with RP (10.2%) recovered clinically at the end of third post-RT month. PFT and HRCT parameters were similar before and after RT overall, as well as by RP and the radiation field subgroups. ROC analysis revealed the significant role of the ipsilateral V5 (cutoff value of 45.9%, p = 0.039), V10 (29.4%, p = 0.015), V20 (23%, p = 0.017), and MLD (1200 cGy, p = 0.030) in predicting RP. Higher post-RT TGFß1 levels (p = 0.037) were noted overall and in patients with RP. Patient and control groups were similar in terms of frequencies of SNPs genotyped for TGFß1 (rs11466345 and rs1800470). EORTC QLQ-C30 and QLQ-BR-23 scores were similar in patients with vs. without RP. CONCLUSION: Our findings revealed significant role of dosimetric factors including MLD, V20 as well as the low dose-volume metrics in predicting the risk of RP among breast cancer patients who received post-operative RT. Implementation of RT, extent of radiation field or the presence of RP had no significant impact on PFTs.


Assuntos
Neoplasias da Mama , Pulmão , Pneumonite por Radiação , Radioterapia Adjuvante , Feminino , Humanos , Neoplasias da Mama/genética , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Seguimentos , Pulmão/fisiopatologia , Pulmão/efeitos da radiação , Polimorfismo de Nucleotídeo Único , Estudos Prospectivos , Qualidade de Vida , Pneumonite por Radiação/etiologia , Pneumonite por Radiação/genética , Pneumonite por Radiação/fisiopatologia , Dosagem Radioterapêutica , Radioterapia Adjuvante/efeitos adversos , Testes de Função Respiratória
2.
Photochem Photobiol Sci ; 21(7): 1299-1308, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35426610

RESUMO

The aim of this study was to evaluate photobiomodulation effects on mRNA relative levels from genes of base excision repair and genomic stabilization in heart tissue from an experimental model of acute lung injury by sepsis. For experimental procedure, animals were randomly assigned to six main groups: (1) control group was animals treated with intraperitoneal saline solution; (2) LASER-10 was animals treated with intraperitoneal saline solution and exposed to an infrared laser at 10 J cm-2; (3) LASER-20 was animals treated with intraperitoneal saline solution and exposed to an infrared laser at 20 J cm-2; (4) acute lung injury (ALI) was animals treated with intraperitoneal LPS (10 mg kg-1); (5) ALI-LASER10 was animals treated with intraperitoneal LPS (10 mg kg-1) and, after 4 h, exposed to an infrared laser at 10 J cm-2 and (6) ALI-LASER20 was animals treated with intraperitoneal LPS (10 mg kg-1) and, after 4 h, exposed to an infrared laser at 20 J cm-2. Irradiation was performed only once and animal euthanasias for analysis of mRNA relative levels by RT-qPCR. Our results showed that there was a reduction of mRNA relative levels from ATM gene and an increase of mRNA relative levels from P53 gene in the heart of animals with ALI when compared to the control group. In addition, there was an increase of mRNA relative levels from OGG1 and APE1 gene in hearts from animals with ALI when compared to the control group. After irradiation, an increase of mRNA relative levels from ATM and OGG1 gene was observed at 20 J cm-2. In conclusion, low-power laser modulates the mRNA relative levels from genes of base excision repair and genomic stabilization in the experimental model of acute lung injury evaluated.


Assuntos
Lesão Pulmonar Aguda , Lipopolissacarídeos , Lesão Pulmonar Aguda/genética , Animais , Reparo do DNA , Genômica , Lasers , Lipopolissacarídeos/farmacologia , Pulmão/efeitos da radiação , Modelos Teóricos , RNA Mensageiro/genética , Solução Salina
3.
Radiother Oncol ; 166: 133-136, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34838890

RESUMO

This is a paired prospective comparative cohort study with 58 patients, in order to analyze the clinical LD-WLI in patients with moderate or severe COVID19 pneumonia. The results of this study show that the Radiotherapy could be an option to improve the clinical response for patients with COVID-19.


Assuntos
COVID-19 , COVID-19/radioterapia , Estudos de Coortes , Humanos , Pulmão/efeitos da radiação , Estudos Prospectivos , SARS-CoV-2 , Resultado do Tratamento
4.
Lasers Med Sci ; 37(2): 1101-1109, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34146193

RESUMO

Asthma is a chronic inflammatory disease characterized by recurrent and reversible episodes of wheezing, dyspnea, chest stiffness, and cough. Its treatment includes several drugs, high cost, and considerable side effects. Photobiomodulation (PBM) emerges as an alternative treatment, showing good results, and it can be applied locally or systemically. Here, we aim to evaluate the effect of transcutaneous systemic photobiomodulation (TSPBM) by red diode light. Therefore, adult rats were sensitized and challenged with ovalbumin (OVA) plus alum for induction of asthma and irradiated or not with TSPBM in the caudal vein (wavelength 660 ± 10 nm; total radiant emission 15 J; area 2.8 cm2; energy density 5.35 J/cm2; irradiance 33.3 mW/cm2; exposure time 150 s). Our investigations prioritized the cell migration into the alveolar space and lung, tracheal responsiveness, release and gene expression of cytokines, mast cell degranulation, and anaphylactic antibodies. Our results showed that TSPBM reduced the cell migration and mast cell degranulation without altering the tracheal responsiveness and ovalbumin antibody titers. Indeed, TSPBM increased the levels of interleukin 10 (IL-10) in the BAL fluid without altering the gene expression of cytokines in the lung tissue. Thus, this study showed that transcutaneous systemic irradiation reduced lung inflammation by altering mast cells degranulation and IL-10 level. Considering that this study is a pioneer in the used of light by the systemic route to treat asthma, the data are interesting and instigate future investigations, mainly in relation to the mechanisms involved and in dosimetry.


Assuntos
Asma , Pneumonia , Animais , Asma/tratamento farmacológico , Asma/radioterapia , Degranulação Celular , Citocinas/metabolismo , Modelos Animais de Doenças , Interleucina-10/metabolismo , Pulmão/efeitos da radiação , Mastócitos/metabolismo , Camundongos , Camundongos Endogâmicos BALB C , Modelos Teóricos , Ovalbumina/metabolismo , Ovalbumina/farmacologia , Ratos
5.
Clin Transl Oncol ; 23(11): 2358-2367, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34043153

RESUMO

PURPOSE: To explore the feasibility of image-guided and respiratory-gated Stereotactic Body Radiation Therapy (SBRT) for Accelerated Partial Breast Irradiation (APBI) in patients with very early breast cancer. MATERIAL AND METHODS: Selected patients with early breast carcinoma after breast-conserving surgery were enrolled in this phase II trial. A fiducial marker was percutaneously placed close to surgical bed and five external fiducials were set on the skin. A CT scan for planning was acquired at free breathing. The treatment was planned and DVH were assessed according to international recommendations. Prescription dose was 30 Gy in five consecutive fractions of 6 Gy. A 6MV monoenergetic LINAC (linear accelerator) that combines stereoscopic X-ray imaging system and ExacTrac Adaptive Gating technique was used. PTV (planning target volume) intrafraction motion was controlled and PTV was irradiated in a selected gated area of the respiratory cycle. Shifts for a correct, gated set-up were calculated and automatically applied. RESULTS: Between April 2013 and October 2015, a total of 23 patients were included. The median tumor size was 12 mm. The mean PTV volume was 114 cc. The mean ipsilateral lung V9 Gy was 2.2% and for left-sided breast cancers, the volume of the heart receiving 1.5 Gy was 11.5%. Maximum skin dose was 30.8 Gy. Acute toxicity was grade1 in all the patients and 100% experienced excellent/good breast cosmesis outcomes. With a median follow-up of 66 months (range 8-99 months) local-relapse-free-survival reaches 100%. One patient developed a second breast cancer outside the treated quadrant after 25.1 months. CONCLUSION: APBI with SBRT and ExacTrac Adaptive Gating System was feasible. The acute and late toxicities were almost null and cosmesis was excellent. We also found that the margins of 5 mm applied from CTV to PTV were sufficient to compensate for geometric uncertainties.


Assuntos
Neoplasias da Mama/radioterapia , Carcinoma Ductal de Mama/radioterapia , Radiocirurgia/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/cirurgia , Intervalo Livre de Doença , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Feminino , Marcadores Fiduciais , Coração/efeitos da radiação , Humanos , Pulmão/efeitos da radiação , Mastectomia Segmentar , Pessoa de Meia-Idade , Movimentos dos Órgãos , Órgãos em Risco/efeitos da radiação , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Radiocirurgia/instrumentação , Respiração , Pele/efeitos da radiação , Fatores de Tempo , Tomografia Computadorizada por Raios X , Carga Tumoral
6.
Clin Transl Oncol ; 23(9): 1915-1922, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33830442

RESUMO

BACKGROUND AND PURPOSE: Synchronous bilateral breast cancer (SBBC) accounts for 1-3.5% of breast cancer patients. The aim of this study was to evaluate dosimetric issues, clinical outcomes, and acute toxicities for SBBC patients receiving synchronous bilateral hypofractionated radiotherapy (SBHRT) and to compare them with patients treated with synchronous bilateral normofractionated RT schedule (SBNRT). MATERIALS AND METHODS: From April 2016 to March 2020, 39 SBBC patients were referred to our institution. Patients were divided according to their prescription dose: Group A: 50 Gy/25fx (fractions), B: 60-64 Gy/25fx, C: 40.05 Gy/15fx; D: 48 Gy/15fx. Toxicity was evaluated using Common Terminology Criteria for Adverse Events (CTCAE)v.5.0. RESULTS: 34 patients were finally evaluated. Median follow-up was 24 months for NF schedule and 9 months for HF schedule. In the HF schedule, no acute side-effects > G2 were observed and no dermatitis was reported in 6th month´s assessments. 95% of patients have no evidence of disease and only 1 patient presented local relapse in the first mammography after RT. No distant failures or deaths were observed. Regarding dosimetric issues, the inter-patient average Dmean for the heart was: Group A: 5.0 Gy (4.6-5.5), Group B: 4.4 Gy (4.1-5.4), Group C: 4.8 Gy (4.5-5.1) and Group D: 5.3 Gy (4.4-5.6). For the lungs, the inter-patient average Dmean was: Group A: 10.8 Gy (9.8-12.2), Group B: 11.5 Gy (11.3-12), Group C: 9.8 Gy (9.3-10.5) and Group D: 10.5 Gy (10-11.3). CONCLUSIONS: This is the first study reporting the safety, feasibility, and tolerability of 40.05 Gy/15fx over 3 weeks for the treatment of SBBC patients. Further study with larger accrual is mandatory.


Assuntos
Neoplasias da Mama/radioterapia , Neoplasias Primárias Múltiplas/radioterapia , Hipofracionamento da Dose de Radiação , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Estudos de Viabilidade , Feminino , Seguimentos , Coração/efeitos da radiação , Humanos , Pulmão/efeitos da radiação , Neoplasias Primárias Múltiplas/diagnóstico por imagem , Neoplasias Primárias Múltiplas/cirurgia , Órgãos em Risco/efeitos da radiação , Estudos Prospectivos , Radioterapia de Intensidade Modulada/efeitos adversos , Fatores de Tempo
7.
Lasers Med Sci ; 36(5): 965-973, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32812131

RESUMO

Acute lung injury (ALI) is a severe, multifactorial lung pathology characterized by diffuse alveolar injury, inflammatory cell infiltration, alveolar epithelial barrier rupture, alveolar edema, and impaired pulmonary gas exchange, with a high rate of mortality; and sepsis is its most common cause. The mechanisms underlying ALI due to systemic inflammation were investigated experimentally by systemic lipopolysaccharide (LPS) administration. Photobiomodulation (PBM) has been showing good results for several inflammatory diseases, but there are not enough studies to support the real benefits of its use, especially systemically. Considering that ALI is a pathology with high morbidity and mortality, we studied the effect of systemic PBM with red light-emitting diode (LED) (wavelength 660 nm; potency 100 mW; energy density 5 J/cm; total energy 15 J; time 150 s) in the management of inflammatory parameters of this disease. For this, 54 male Wistar rats were submitted to ALI by LPS injection (IP) and treated or not with PBM systemically in the tail 2 and 6 h after LPS injection. Data were analyzed by one-way ANOVA followed by Student's Newman-Keuls. Our results point to the beneficial effects of systemic PBM on the LPS-induced ALI, as it reduced the number of neutrophils recruited into the bronchoalveolar lavage, myeloperoxidase activity, and also reduced interleukins (IL) 1ß, IL-6, and IL-17 in the lung. Even considering the promising results, we highlight the importance of further studies to understand the mechanisms involved, and especially the dosimetry, so that in near future, we can apply this knowledge in clinical practice.


Assuntos
Lesão Pulmonar Aguda/radioterapia , Terapia com Luz de Baixa Intensidade , Lesão Pulmonar Aguda/metabolismo , Lesão Pulmonar Aguda/patologia , Animais , Lavagem Broncoalveolar , Progressão da Doença , Interleucinas/metabolismo , Pulmão/metabolismo , Pulmão/patologia , Pulmão/efeitos da radiação , Masculino , Ratos , Ratos Wistar , Resultado do Tratamento
8.
Int J Radiat Biol ; 97(2): 120-125, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33164596

RESUMO

BACKGROUND: Recently, low dose radiotherapy delivered to the whole lung has been proposed as treatment for the pneumonia due to COVID-19. Although there is biological plausibility for its use, the evidence supporting its effectiveness is scarce, and the risks associated with it may be significant. Thus, based on a virtual case simulation, we estimated the risks of radiation-induced cancer (RIC) and cardiac disease. METHODS: Lifetime attributable risks (LAR) of RIC were calculated for the lung, liver, esophagus, and breast of female patients. The cardiovascular risk of exposure-induced death (REID) due to ischemic heart disease was also calculated. The doses received by the organs involved in the treatment were obtained from a simulation of conformal radiotherapy (RT) treatment, delivering a dose of 0.5 Gy-1.5 Gy to the lungs. We considered a LAR and REID <1% as acceptable, 1-2% cautionary, and >2% unacceptable. RESULTS: The lung was at the highest risk for RIC (absolute LAR below 5200 cases/100,000 and 2250 cases/100,000 for women and men, respectively). For women, the breast had the second-highest LAR, especially for young women. The liver and esophagus had LARs below 700/100,000 for both sexes, with a higher incidence of esophageal cancer in women and liver cancer in men. Regarding the LAR cutoff, we observed an unacceptable or cautionary LAR for lung cancer in all women and men <60 years with an RT dose >1 Gy. LAR for lung cancer with an RT dose of 1 Gy was cautionary for women >60 years of age and men <40 years of age. No LAR estimation was unacceptable for the RT dose ≤0.7 Gy in all groups irrespective of sex or age at exposure. Only 0.5 Gy had an acceptable REID. CONCLUSIONS: A RT dose ≤0.5 Gy provides an acceptable LAR estimate (≤1%) for RIC and REID, irrespective of sex and age. The current ongoing trials should initially use doses ≤0.5 Gy to maintain the risks at an acceptable level and include only patients who fail or do not have any other treatment option.


Assuntos
COVID-19/radioterapia , Pulmão/efeitos da radiação , Isquemia Miocárdica/etiologia , Neoplasias Induzidas por Radiação/etiologia , Doses de Radiação , Feminino , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia Conformacional/efeitos adversos , Medição de Risco , Interface Usuário-Computador
9.
PLoS One ; 15(10): e0238704, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33035214

RESUMO

The aim of this work was to use TOPAS Monte Carlo simulations to model the effect of magnetic fields on dose distributions in brachytherapy lung treatments, under ideal and clinical conditions. Idealistic studies were modeled consisting of either a monoenergetic electron source of 432 keV, or a polyenergetic electron source using the spectrum of secondary electrons produced by 192Ir gamma-ray irradiation. The electron source was positioned in the center of a homogeneous, lung tissue phantom (ρ = 0.26 g/cm3). Conversely, the clinical study was simulated using the VariSource VS2000 192Ir source in a patient with a lung tumor. Three contoured volumes were considered: the tumor, the planning tumor volume (PTV), and the lung. In all studies, dose distributions were calculated in the presence or absence of a constant magnetic field of 3T. Also, TG-43 parameters were calculated for the VariSource and compared with published data from EGS-brachy (EGSnrc) and PENELOPE. The magnetic field affected the dose distributions in the idealistic studies. For the monoenergetic and poly-energetic studies, the radial distance of the 10% iso-dose line was reduced in the presence of the magnetic field by 64.9% and 24.6%, respectively. For the clinical study, the magnetic field caused differences of 10% on average in the patient dose distributions. Nevertheless, differences in dose-volume histograms were below 2%. Finally, for TG-43 parameters, the dose-rate constant from TOPAS differed by 0.09% ± 0.33% and 0.18% ± 0.33% with respect to EGS-brachy and PENELOPE, respectively. The geometry and anisotropy functions differed within 1.2% ± 1.1%, and within 0.0% ± 0.3%, respectively. The Lorentz forces inside a 3T magnetic resonance machine during 192Ir brachytherapy treatment of the lung are not large enough to affect the tumor dose distributions significantly, as expected. Nevertheless, large local differences were found in the lung tissue. Applications of this effect are therefore limited by the fact that meaningful differences appeared only in regions containing air, which is not abundant inside the human.


Assuntos
Braquiterapia/métodos , Neoplasias Pulmonares/radioterapia , Pulmão/efeitos da radiação , Campos Magnéticos , Braquiterapia/estatística & dados numéricos , Simulação por Computador , Relação Dose-Resposta à Radiação , Elétrons , Humanos , Radioisótopos de Irídio/administração & dosagem , Radioisótopos de Irídio/farmacocinética , Radioisótopos de Irídio/uso terapêutico , Imageamento por Ressonância Magnética , Método de Monte Carlo , Imagens de Fantasmas , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/farmacocinética , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Distribuição Tecidual
10.
Clin Transl Oncol ; 21(11): 1492-1498, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30875061

RESUMO

PURPOSE: To evaluate acute and late skin/subcutaneous toxicities and radiation-induced lung fibrosis (RILF) in patients treated with adjuvant radiotherapy (RT) for synchronous bilateral breast cancers (SBBC), after conservative surgery. METHODS/PATIENTS: Twenty-five patients were treated with volumetric-modulated arc therapy (VMAT/RapidArc®) on both breasts, and checked clinically for detecting RT toxicities during and after treatment. A high-resolution computed tomography (HRCT) was performed, for detecting RILF during follow-up. RESULTS: We registered acute Grade-1 skin toxicity in 18 patients (72%), while six patients (24%) experienced Grade-2 toxicity. No breath symptoms were reported during and after RT. Late Grade-1 subcutaneous toxicity and late Grade-2 skin toxicity were registered in four patients (16%) and one patient (4%), respectively, at a mean follow-up of 36 months. Grade-1 RILF was detected in six patients (30%). The median volume of fibrosis area was 6.5 cc (range 1.3-21.5 cc). The partial volumes receiving a specified dose (V20, V30, V40, and V50) in patients who developed lung fibrosis were significantly bigger than who did not (p < 0.01). We showed that the mean volume of the tumour boost of patients who developed fibrosis (77.7 cc) was not significantly different from the other patients (90.8 cc) (p = 0.5). CONCLUSION: The clinical impact of this technique is favourable, and this is the first clinical study showing RILF by HRCT in a setting of SBBC. Further study with larger accrual is mandatory.


Assuntos
Neoplasias da Mama/radioterapia , Pulmão/efeitos da radiação , Neoplasias Primárias Múltiplas/radioterapia , Pneumonite por Radiação/etiologia , Radioterapia de Intensidade Modulada/efeitos adversos , Pele/efeitos da radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pessoa de Meia-Idade , Neoplasias Primárias Múltiplas/diagnóstico por imagem , Órgãos em Risco/diagnóstico por imagem , Órgãos em Risco/efeitos da radiação , Pneumonite por Radiação/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Adjuvante/efeitos adversos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA