1.
Trop Anim Health Prod ; 52(6): 3725-3733, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33009587

RESUMO

The objective of this study was to evaluate the viability of using transponders for the electronic identification of water buffaloes and compare their efficiency when used in animals of different age groups. Electronic transponders with RFID technology (2.1 × 12.2 mm) were implanted subcutaneously (D0) in the scutiform cartilage. The animals consisted of four groups: CLF-I (17 calves; 2.1 ± 1.9 months), CLF-II (20 calves; 5.1 ± 3.2 months), HFR (20 heifers; 22 ± 4.7 months) and STR (19 steers; 26.6 ± 6.7 months). The animals were kept under pasture grazing, a part of the year in the dryland and a part in the floodplain, and were monitored for up to 350 days. The average time required for individual transponder implant was 49.46 s, while the time required for reading the code was 3.76 s. The older calves required higher time for individual implant (P = 0.0001) and closer approximation of the reader in the D150 (P = 0.0001). The mean read distance was 2.98 cm in D0 and 1.94 cm in D150. The magnitude of the subcutaneous transponder migration was minimal, and was within an area of 17.2 mm2. A slight bleeding was observed in 15.79% of the animals during the implant. A decreasing incidence of edema was observed until D21, with the heifers being more sensitive until that time (P = 0.0099). Considering the results, it is preferred to implant electronic transponders in calves up to two months of age. The physical rate of transponder loss was 1.3% and the loss of functionality was 9.2%. High reading rate was achieved when animals were raised both in dryland (93.9%) and floodplain (97.2%). Thus, the electronic identification of water buffaloes is a technique capable of replacing traditional and rudimentary methods to identify buffaloes and can provide safe identification of animals.


Assuntos
Sistemas de Identificação Animal/veterinária , Búfalos , Envelhecimento , Sistemas de Identificação Animal/instrumentação , Animais , Feminino , Masculino
2.
J Anim Sci ; 92(6): 2686-92, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24753380

RESUMO

Electronic identification of animals has become increasingly important worldwide to improve and ensure traceability. In warm and hot climates, such as Brazil, boluses can have advantages over ear tags as the internal devices reduce the risks of ear tag losses, tissue damage, and lesions on the ear. Electronic boluses, however, are often perceived as having negative characteristics, including reported difficulties of administration in small ruminants. This paper describes the factors associated with bolus design that affect the swallowing of a bolus in sheep. Other factors that might influence bolus swallowing time have also been considered. In addition, the effect of bolus design on its performance was evaluated. A total of 56 Suffolk ewes were used to assess the ease of administration and retention of 3 types of electronic ruminal boluses (mini, 11.5 × 58.0 mm and 21.7 g; small, 14.8 × 48.5 mm and 29.5 g; standard, 19.3 × 69.8 mm and 74.4 g) during a whole productive year, including pregnancy and lamb suckling. Ewe age (5.6 ± 2.3 yr) and weight (85.07 ± 8.2 kg BW) were recorded, as well as time for bolus swallowing. The deglutition of the bolus and any resulting blockages in the esophagus were monitored by visual observations. Retention and readability of the boluses were regularly monitored for d 1, wk 1, mo 1, and every mo until 1 yr. Time for bolus swallowing differed substantially with bolus type and was greater (P < 0.05) for the standard bolus (32.8 ± 6.9 s) when compared to small and mini boluses, which did not differ (8.5 ± 2.0 vs. 9.2 ± 2.7 s; P > 0.05). The bolus o.d. and length were positively correlated with swallowing time (P < 0.01). The ewe weight was negatively correlated with swallowing time (P < 0.05). At 6 mo all electronic boluses showed 100% retention rate, and at 12 mo, bolus retention was 100%, 94.5%, and 100% for mini, small, and standard boluses, respectively (P > 0.05). At 12 mo, all boluses showed 100% readability, except for small boluses, which had a readability of 94.5%. In conclusion, bolus design affected swallowing time and bolus readability. A reduction in boluses length and o.d. needs to be carried out to provide ease of administration and for boluses to be used as an effective means of electronic identification. Therefore, this study shows that adequately designed boluses are safe and suitable for identifying adult sheep and can therefore be used in hot climates.


Assuntos
Sistemas de Identificação Animal/instrumentação , Sistemas de Identificação Animal/métodos , Rúmen , Sistemas de Identificação Animal/normas , Animais , Peso Corporal , Brasil , Deglutição/fisiologia , Eletrônica/instrumentação , Desenho de Equipamento , Feminino , Ovinos , Carneiro Doméstico , Fatores de Tempo
4.
J Wildl Dis ; 44(4): 979-82, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18957654

RESUMO

Six free-ranging marine otters (Lontra felina) were livetrapped on the central coast of Chile and implanted with specially designed radiotransmitters as part of a spatial ecology study. Marine otters frequent the rocky seashore, often squeezing their narrow bodies through cracks and crevices and grooming themselves on the rocks. They are also among the smallest of the otter species, weighing between 3.4 kg and 4.5 kg. For these reasons, the transmitter used was small, rectangular, and flat, measuring 3.5 x 3.2 x 1.0 cm. They were implanted using a ventral midline approach to minimize contact between the skin incision and sharp-edged rocks. Surgical incisions healed within 2 wk. The transmitters functioned well, but the duration varied from 62 days to 143 days instead of the 240 days predicted by the manufacturer. All six marine otters reestablished in their home ranges, and survey results suggest they survived well beyond the life of the transmitters.


Assuntos
Sistemas de Identificação Animal/instrumentação , Sistemas de Identificação Animal/métodos , Lontras/cirurgia , Próteses e Implantes/veterinária , Telemetria/veterinária , Músculos Abdominais/cirurgia , Animais , Chile , Feminino , Masculino , Telemetria/instrumentação , Telemetria/métodos , Fatores de Tempo
6.
Nature ; 434(7037): 1121-7, 2005 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-15858572

RESUMO

Electronic tags that archive or transmit stored data to satellites have advanced the mapping of habitats used by highly migratory fish in pelagic ecosystems. Here we report on the electronic tagging of 772 Atlantic bluefin tuna in the western Atlantic Ocean in an effort to identify population structure. Reporting electronic tags provided accurate location data that show the extensive migrations of individual fish (n = 330). Geoposition data delineate two populations, one using spawning grounds in the Gulf of Mexico and another from the Mediterranean Sea. Transatlantic movements of western-tagged bluefin tuna reveal site fidelity to known spawning areas in the Mediterranean Sea. Bluefin tuna that occupy western spawning grounds move to central and eastern Atlantic foraging grounds. Our results are consistent with two populations of bluefin tuna with distinct spawning areas that overlap on North Atlantic foraging grounds. Electronic tagging locations, when combined with US pelagic longline observer and logbook catch data, identify hot spots for spawning bluefin tuna in the northern slope waters of the Gulf of Mexico. Restrictions on the time and area where longlining occurs would reduce incidental catch mortalities on western spawning grounds.


Assuntos
Sistemas de Identificação Animal/métodos , Migração Animal , Eletrônica , Atum/fisiologia , Sistemas de Identificação Animal/instrumentação , Animais , Oceano Atlântico , Meio Ambiente , Comportamento Alimentar/fisiologia , Mar Mediterrâneo , México , Dinâmica Populacional , Reprodução/fisiologia , Água do Mar , Temperatura , Fatores de Tempo