Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.653
Filtrar
1.
J Exp Biol ; 227(15)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39136099

RESUMO

The presence of cardiac shunts in ectothermic tetrapods is thought to be consistent with active vascular modulations for proper hemodynamic support. Local control of blood flow modulates tissue perfusion and thus systemic conductance (Gsys) is assumed to increase with body temperature (Tb) to accommodate higher aerobic demand. However, the general increase of Gsys presses for a higher right-to-left (R-L) shunt, which reduces arterial oxygen concentration. In contrast, Tb reduction leads to a Gsys decrease and a left-to-right shunt, which purportedly increases pulmonary perfusion and plasma filtration in the respiratory area. This investigation addressed the role of compensatory vascular adjustments in the face of the metabolic alterations caused by Tb change in the South American rattlesnake (Crotalus durissus). Cardiovascular recordings were performed in decerebrated rattlesnake preparations at 10, 20 and 30°C. The rise in Tb increased metabolic demand, and correlated with an augmentation in heart rate. Although cardiac output increased, systemic stroke volume reduced while pulmonary stroke volume remained stable. Although that resulted in a proportionally higher increase in pulmonary blood flow, the R-L shunt was maintained. While the systemic compliance of large arteries was the most relevant factor in regulating arterial systemic blood pressure, peripheral conductance of pulmonary circulation was the major factor influencing the final cardiac shunt. Such dynamic adjustment of systemic compliance and pulmonary resistance for shunt modulation has not been demonstrated before and contrasts with previous knowledge on shunt control.


Assuntos
Crotalus , Hemodinâmica , Animais , Crotalus/fisiologia , Temperatura Corporal/fisiologia , Frequência Cardíaca/fisiologia , Temperatura , Débito Cardíaco/fisiologia , Circulação Pulmonar/fisiologia , Masculino , Serpentes Peçonhentas
2.
J Therm Biol ; 123: 103907, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38950497

RESUMO

Recent heatwaves have highlighted the importance of accurate and continuous core temperature (TCORE) monitoring in sports settings. For example, accentuated rises in TCORE caused by physical exercises under environmental heat stress increase the risk of heat illnesses. Thus, using valid and reproducible devices is essential to ensure safe sports practice. In this study, we assessed the validity and reproducibility of the Calera Research Sensor (CRS) in estimating the TCORE of male and female participants during cycling exercise in a hot environment. Seven male (age: 36.2 ± 10.1 years) and eight female cyclists (age: 30.1 ± 5.0 years) underwent two identical cycling trials in a dry-bulb temperature of 32 °C and relative humidity of 60%. The protocol consisted of an initial 10-min rest followed by a 60-min exercise comprising 10 min at 20%, 25 min at 55%, and 25 min at 75% of maximal aerobic power, and an additional 25 min of post-exercise recovery. TCORE was recorded simultaneously every minute using a gastrointestinal capsule (TGi) and the CRS (TSENSOR). Bland-Altman analysis was performed to calculate bias, upper (LCS) and lower (LCI) concordance limits, and the 95% confidence interval (95%CI). The maximum acceptable difference between the two devices was predetermined at ±0.4 °C. A mixed linear model was used to assess the paired differences between the two measurement systems, considering the participants, trials, and environmental conditions as random effects and the cycling stages as fixed effects. An intra-class correlation coefficient (ICC) of 0.98 was recorded when analyzing data from the entire experiment. A non-significant bias value of 0.01 °C, LCS of 0.38 °C, LCI of -0.35 °C, and CI95% of ±0.36 °C were found. When analyzing data according to the participants' sex, CRS reproducibility was high in both sexes: ICC values of 0.98 and 0.99 were reported for males and females, respectively. CI95% was 0.35 °C in experiments with males and 0.37 °C with females, thereby falling within the acceptable margin of difference. Therefore, CRS was considered valid (compared to TGi) and reproducible in estimating TCORE in both sexes at various intensities of cycling exercise in the heat.


Assuntos
Ciclismo , Temperatura Corporal , Temperatura Alta , Humanos , Masculino , Adulto , Feminino , Ciclismo/fisiologia , Reprodutibilidade dos Testes , Exercício Físico , Adulto Jovem
3.
Physiol Rep ; 12(14): e16155, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39039617

RESUMO

Numerous body locations have been utilized to obtain an accurate body temperature. While some are commonly used, their accuracy, response time, invasiveness varies greatly, and determines their potential clinical and/or research use. This review discusses human body temperature locations, their accuracy, ease of use, advantages, and drawbacks. We explain the concept of core body temperature and which of the locations achieve the best correlation to this temperature. The body locations include axilla, oral cavity, rectum, digestive and urinary tracts, skin, tympanic, nasopharynx, esophagus, and pulmonary artery. The review also discusses the latest temperature technologies, heat-flux technology and telemetric ingestible temperature pills, and the body locations used to validate these devices. Rectal and esophageal measurements are the most frequently used.


Assuntos
Temperatura Corporal , Humanos , Temperatura Corporal/fisiologia , Termografia/métodos , Termografia/instrumentação , Termometria/métodos , Termometria/instrumentação
4.
Psychophysiology ; 61(9): e14601, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38708795

RESUMO

Physiologically based stress detection systems have proven to be effective in identifying different stress conditions in the body to determine the source of stress and be able to counteract it. However, some stress conditions have not been widely studied, including thermal stress, cognitive stress, and combined (thermal-cognitive) stress conditions, which are frequently encountered in work or school environments. In order to develop systems to detect and differentiate these conditions, it is necessary to identify the physiological indicators that characterize each of them. The present research aims to identify which physiological indicators (heart rate, respiratory rate, galvanic skin response, and local temperature) could differentiate different stress conditions (no-stress, cognitive stress, thermal stress, and combined (thermal-cognitive) stress conditions). Thirty participants were exposed to cognitive, thermal, and combined stress sources while recording their physiological signals. The findings indicate that both mean heart rate and mean galvanic skin response identify moderate thermal and cognitive stress conditions as distinct from a no-stress condition, yet they do not differentiate between the two stress conditions. Additionally, heart rate uniquely identifies the cognitive-thermal stress condition, effectively distinguishing this combined stress condition from the singular stress conditions and the no-stress condition. Mean local temperature specifically signals thermal stress conditions, whereas mean respiratory rate accurately identifies cognitive stress conditions, with both indicators effectively separating these conditions from each other and from the no-stress condition. This is the first basis for differentiating thermal and cognitive stress conditions through physiological indicators.


Assuntos
Resposta Galvânica da Pele , Frequência Cardíaca , Taxa Respiratória , Estresse Psicológico , Humanos , Frequência Cardíaca/fisiologia , Resposta Galvânica da Pele/fisiologia , Masculino , Feminino , Estresse Psicológico/fisiopatologia , Taxa Respiratória/fisiologia , Adulto Jovem , Adulto , Cognição/fisiologia , Estresse Fisiológico/fisiologia , Temperatura Corporal/fisiologia
5.
J Med Primatol ; 53(3): e12711, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38790083

RESUMO

BACKGROUND: This study used infrared thermography (IRT) for mapping the facial and ocular temperatures of howler monkeys, to determine parameters for the diagnosis of febrile processes. There are no published IRT study in this species. METHODS: Were evaluated images of a group of monkeys kept under human care at Sorocaba Zoo (São Paulo, Brazil). The images were recorded during 1 year, in all seasons. Face and eye temperatures were evaluated. RESULTS: There are statistically significant differences in face and eye temperatures. Mean values and standard deviations for facial and ocular temperature were respectively: 33.0°C (2.1) and 36.5°C (1.9) in the summer; 31.5°C (4.5) and 35.3°C (3.6) in the autumn; 30.0°C (4.3) and 35.6°C (3.9) in the winter; 30.8°C (2.9) and 35.5°C (2.1) in the spring. CONCLUSIONS: The IRT was effective to establish a parameter for facial and ocular temperatures of black-and-gold howler monkeys kept under human care.


Assuntos
Alouatta , Temperatura Corporal , Olho , Face , Raios Infravermelhos , Termografia , Animais , Termografia/veterinária , Termografia/métodos , Alouatta/fisiologia , Masculino , Estações do Ano , Feminino , Febre/veterinária , Febre/diagnóstico , Animais de Zoológico
6.
PLoS One ; 19(5): e0301083, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38787875

RESUMO

Resilience of mammals to anthropogenic climate and land-use changes is associated with the maintenance of adequate responses of several fitness-related traits such as those related to immune functions. Isolated and combined effects of decreased food availability and increased ambient temperature can lead to immunosuppression and greater susceptibility to disease. Our study tested the general hypothesis that decreased food availability, increased ambient temperature and the combined effect of both factors would affect selected physiological and behavioral components associated with the innate immune system of fruit-eating bats (Carollia perspicillata). Physiological (fever, leukocytosis and neutrophil/lymphocyte ratio) and behavioral (food intake) components of the acute phase response, as well as bacterial killing ability of the plasma were assessed after immune challenge with lipopolysaccharide (LPS: 10 mg/kg) in experimental groups kept at different short-term conditions of food availability (ad libitum diet or 50% food-deprived) and ambient temperature (27 and 33°C). Our results indicate that magnitude of increase in body temperature was not affected by food availability, ambient temperature or the interaction of both factors, but the time to reach the highest increase took longer in LPS-injected bats that were kept under food restriction. The magnitude of increased neutrophil/lymphocyte ratio was affected by the interaction between food availability and ambient temperature, but food intake, total white blood cell count and bacterial killing ability were not affected by any factor or interaction. Overall, our results suggest that bacterial killing ability and most components of acute phase response examined are not affected by short-term changes in food availability and ambient temperature within the range evaluated in this study, and that the increase of the neutrophil/lymphocyte ratio when bats are exposed to low food availability and high ambient temperature might represent an enhancement of cellular response to deal with infection.


Assuntos
Quirópteros , Imunidade Inata , Lipopolissacarídeos , Temperatura , Animais , Quirópteros/imunologia , Quirópteros/fisiologia , Imunidade Inata/efeitos dos fármacos , Lipopolissacarídeos/farmacologia , Neutrófilos/imunologia , Masculino , Ingestão de Alimentos , Frutas/imunologia , Temperatura Corporal , Reação de Fase Aguda/imunologia
7.
Oper Dent ; 49(3): 262-272, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38632866

RESUMO

OBJECTIVES: This study evaluated the influence of hydrogen peroxide (HP) with or without titanium dioxide nanotubes (TiO2) associated with violet LED (VL) regarding: a) the temperature change in the pulp chamber and facial surface; b) the decomposition of HP; and c) the cytotoxicity of the gels on pulp cells. METHODS AND MATERIALS: The experimental groups were: HP35 (35% HP/Whiteness HP, FGM); HP35+VL; HP35T (HP35+TiO2); HP35T+VL; HP7 (7.5% HP/White Class 7.5%, FGM); HP7+VL; HP7T (HP7+TiO2); and HP7T+VL. TiO2 was incorporated into the bleaching gels at 1%. Eighty bovine incisors were evaluated to determine temperature change in 8 experimental groups (n=10/group). A k-type thermocouple was used to evaluate the temperatures of the facial surface and in the pulp chamber, achieved by enabling endodontic access to the palatal surface, throughout the 30-minute session. HP decomposition (n=3) of gels was evaluated by using an automatic potentiometric titrator at the initial and 30-minute time points. Trans-enamel and trans-dentinal cell viability were assessed with a pulp chamber device as well as enamel and dentin discs (n=6), and the treatment extracts (culture medium + diffused components) were collected and applied to MDPC-23 odontoblast cells to evaluate cell viability according to the MTT test. RESULTS: A temperature increase in the pulp chamber was observed in the presence of VL at 30 minutes (p<0.05) (Mann-Whitney test). Also at 30 minutes, HP35 showed greater decomposition in the presence of VL rather than in its absence (p<0.05) (mixed linear models and the Tukey-Kramer test). HP7 provided greater cell viability than the groups treated with HP35 (p<0.05) (generalized linear models test). Cell viability was significantly lower for HP7 in the presence of VL (p<0.05). CONCLUSION: Pulpal temperature increased with VL (maximum of 1.9°C), but did not exceed the critical limit to cause pulp damage. Less concentrated HP resulted in higher cell viability, even when associated with VL.


Assuntos
Polpa Dentária , Peróxido de Hidrogênio , Clareamento Dental , Animais , Clareamento Dental/métodos , Polpa Dentária/citologia , Polpa Dentária/efeitos dos fármacos , Bovinos , Peróxido de Hidrogênio/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Clareadores Dentários/farmacologia , Titânio , Temperatura Corporal , Cavidade Pulpar/efeitos dos fármacos
8.
Rev Lat Am Enfermagem ; 32: e4143, 2024.
Artigo em Inglês, Espanhol, Português | MEDLINE | ID: mdl-38655937

RESUMO

OBJECTIVES: this study aimed at estimating and comparing the reliability of temperature measurements obtained using a peripheral infrared temporal thermometer, a central cutaneous thermometer ("Zero-Heat-Flux Cutaneous thermometer") and an esophageal or nasopharyngeal thermometer among elective surgical patients in the intraoperative period. METHOD: a longitudinal study with repeated measures carried out by convenience sampling of 99 patients, aged at least 18 years old, undergoing elective abdominal cancer surgeries, with anesthesia lasting at least one hour, with each patient having their temperature measured by all three methods. RESULTS: the intraclass correlation coefficient showed a low correlation between the measurements using the peripheral temporal thermometer and the central cutaneous (0.0324) and esophageal/nasopharyngeal (-0.138) thermometers. There was a high correlation (0.744) between the central thermometers evaluated. CONCLUSION: the data from the current study do not recommend using infrared temporal thermometers as a strategy for measuring the body temperature of patients undergoing anesthetic-surgical procedures. Central cutaneous thermometers and esophageal/nasopharyngeal thermometers are equivalent for detecting intraoperative hypothermia.


Assuntos
Temperatura Corporal , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Longitudinais , Idoso , Termômetros/normas , Adulto , Período Intraoperatório , Cuidados Intraoperatórios/métodos , Cuidados Intraoperatórios/instrumentação
9.
Sensors (Basel) ; 24(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38544207

RESUMO

The remote monitoring of vital signs and healthcare provision has become an urgent necessity due to the impact of the COVID-19 pandemic on the world. Blood oxygen level, heart rate, and body temperature data are crucial for managing the disease and ensuring timely medical care. This study proposes a low-cost wearable device employing non-contact sensors to monitor, process, and visualize critical variables, focusing on body temperature measurement as a key health indicator. The wearable device developed offers a non-invasive and continuous method to gather wrist and forehead temperature data. However, since there is a discrepancy between wrist and actual forehead temperature, this study incorporates statistical methods and machine learning to estimate the core forehead temperature from the wrist. This research collects 2130 samples from 30 volunteers, and both the statistical least squares method and machine learning via linear regression are applied to analyze these data. It is observed that all models achieve a significant fit, but the third-degree polynomial model stands out in both approaches. It achieves an R2 value of 0.9769 in the statistical analysis and 0.9791 in machine learning.


Assuntos
Temperatura Corporal , Dispositivos Eletrônicos Vestíveis , Humanos , Punho/fisiologia , Temperatura , Pandemias
10.
J Therm Biol ; 121: 103833, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38527387

RESUMO

Dairy cows in pasture-based systems are more susceptible to heat stress. Holstein cows have the black or red phenotypes, the latter having lower absorbance of solar radiation. Therefore, the study's objective was to evaluate whether cows with red (R) coats are more resistant than black (B) cows to hot weather in a subtropical climate. R and B lactating Holstein cows were evaluated during the cold and hot seasons for internal and surface temperature and sweating rate. In the cold season, body temperature (n = 9/group) did not differ between groups, but the average superficial temperature (n = 13/group) was lower in R cows (B: 30.9 ± 0.3 °C; RW: 29.6 ± 0.3 °C; p = 0.02). In the hot season, under mild to moderate heat stress, mean body temperature (n = 9/group) of R cows was lower (B: 38.75 ± 0.01 °C; R: 38.62 ± 0.1 °C; p=<0.0001), whereas no difference was observed in superficial temperature (n = 17/group). The maximum internal temperature and sweating rate (n = 11/group), measured in the hot season, and the number of evaluations in hyperthermia in both seasons did not differ. Therefore, there were differences in thermoregulation between phenotypes under mild to moderate heat stress conditions. However, considering that only discrete differences were observed, the red and white coat is unlikely to benefit the Holstein cow's welfare under mild to moderate thermal stress.


Assuntos
Regulação da Temperatura Corporal , Lactação , Estações do Ano , Animais , Bovinos/fisiologia , Feminino , Brasil , Resposta ao Choque Térmico , Temperatura Alta , Temperatura Corporal , Temperatura Baixa , Sudorese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA