Comparação entre as equações de FAVAD e geral para avaliação da vazão perdida por meio de vazamentos em sistemas urbanos de distribuição de água / Comparison between FAVAD and general equations to evaluate the leakage lost flow in urban water distribution systems
Boian, Raul Francischini; Macedo, Dhiogo Okumoto; Oliveira, Paulo José Alves de; Janzen, Johannes Gerson.
Afiliação
  • Boian, Raul Francischini; Universidade Federal de Mato Grosso do Sul. Campo Grande. BR
  • Macedo, Dhiogo Okumoto; Universidade Federal de Mato Grosso do Sul. Campo Grande. BR
  • Oliveira, Paulo José Alves de; University of Cincinnati. Cincinnati. US
  • Janzen, Johannes Gerson; Universidade Federal de Mato Grosso do Sul. Campo Grande. BR
Eng. sanit. ambient ; 24(6): 1073-1080, nov.-dez. 2019. tab, graf
Article em Pt | LILACS-Express | LILACS | ID: biblio-1056117
Biblioteca responsável: BR1.1
RESUMO
RESUMO Este artigo modela um sistema de distribuição de água (SDA) real com um grande número de vazamentos para determinar se existe diferença entre a vazão perdida pelo SDA predita pela equação de FAVAD e pela equação geral. Foi estudado o efeito da área e da quantidade dos vazamentos não visíveis, da área dos vazamentos potencialmente detectáveis, da carga de pressão e do coeficiente de descarga sobre a vazão perdida do SDA usando planejamento fatorial. Os resultados mostram que os três fatores significativos em ordem decrescente são a área de vazamentos potencialmente detectáveis, a interação entre a área de vazamentos potencialmente detectáveis e a carga de pressão e a área de vazamentos de fundo. A quantidade de vazamentos não visíveis e o coeficiente de descarga não influenciam a diferença entre a equação de FAVAD e a geral, nem como fator principal tampouco como interação com outros fatores.
ABSTRACT
ABSTRACT This paper models a real water distribution system (WDS) with a large number of leaks to determine if there is a difference between the flow lost by the WDS predicted by the FAVAD and the GENERAL equations. The effect of the area and the amount of non-visible/background leaks, the area of potentially detectable leaks, the pressure load and the discharge coefficient on the leakage flow rate in a WDS were studied using factorial design. The results show that the three significant factors in descending order are the area of potentially detectable leaks, the interaction between the area of potentially detectable leaks and the head pressure and the area of background leaks. The amount of background leaks and the discharge coefficient do not influence the difference between the FAVAD and the GENERAL equations, neither as a main factor nor as an interaction with other factors.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Tipo de estudo: Prognostic_studies Idioma: Pt Revista: Eng. sanit. ambient Assunto da revista: SAUDE AMBIENTAL / SAUDE PUBLICA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil / Estados Unidos País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Tipo de estudo: Prognostic_studies Idioma: Pt Revista: Eng. sanit. ambient Assunto da revista: SAUDE AMBIENTAL / SAUDE PUBLICA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil / Estados Unidos País de publicação: Brasil