Correlación de valores B-HCG y ultrasonografia intraoperatoria en embarazo ectópico / CORRELATION OF ß-HCG LEVELS AND INTRA-OPERATIVE ULTRASONOGRAPHY IN ECTOPIC PREGNANCY
Rev. méd. (La Paz)
; 26(1): 18-23, 2020. ilus
Article
em Es
| LILACS
| ID: biblio-1127079
Biblioteca responsável:
BO39.1
RESUMEN
Introducción:
El diagnóstico del embarazo ectópico puede no resultar fácil y se debe realizar con rapidez y seguridad, pues una demora puede conllevar a la ruptura, la hemorragia y poner en peligro la vida de la paciente.Objetivo:
Determinar el grado de correlación de valores de β-hCG y ultrasonografía con los hallazgos intra-operatorios de pacientes con diagnóstico de embarazo ectópico en el servicio de Ginecología y Obstetricia del Hospital Municipal Boliviano Holandés. Material ymétodos:
Estudio descriptivo transversal y retrospectivo. Se estudiaron 115 pacientes con diagnóstico de embarazo ectópico, internadas en el Servicio de Ginecología y Obstetricia del Hospital Municipal Boliviano Holandés, durante el periodo 2010 - 2014.Resultados:
La población con mayor frecuencia afectada, es de 20 a 30 años de edad (88,7%). La mayor cantidad de población, se observó durante el año 2014 (47%). La validez de los hallazgos ultrasonográficos es de Sensibilidad = 98,2% y Especificidad = 75%. La seguridad de los hallazgos ultrasonográficos es de Valor Predictivo Positivo = 99,1% y Valor Predictivo Negativo = 60%. La validez de los hallazgos ultrasonográficos combinado con la cuantificación sérica de β-hCG es de Sensibilidad = 99,1% y Especificidad = 100%. La seguridad de los hallazgos ultrasonográficos combinado con la cuantificación sérica de β-hCG es de Valor Predictivo Positivo = 100% y Valor Predictivo Negativo = 80%.Conclusión:
El test diagnóstico ultrasonográfico combinado con la cuantificación sérica de β-hCG tiene mayor validez y seguridad que el test diagnóstico ultrasonográfico solo.ABSTRACT
Introduction:
The diagnosis for ectopic pregnancy may be difficult, and must be carried out quickly and safely since a delay can lead to rupture, bleeding and endanger the life of the patient.Objective:
To determine the correlation degree of β-hCG levels and ultrasonography with the intra-operative findings of patients with ectopic pregnancy diagnosis in the Gynecology and Obstetrics Service at Hospital Municipal Boliviano Holandés. Material andmethods:
Descriptive, cross-sectional and retrospective study that included 115 patients with ectopic pregnancy diagnosis, and admitted in the Obstetrics and Gynecology Service at Hospital Municipal Boliviano Holandés during the period 2010-2014.Results:
The most frequently affected population was 20 to 30 years old (88.7%). Most of the cases were observed during 2014 (47%). Validity of ultrasound findings reflected 98.2% of sensitivity and 75 % of specificity. Safety of ultrasound findings reflected Positive Predictive Value of 99.1 % and Negative Predictive Value of 60 %. Validity of ultrasound findings combined with β-hCG serum quantification displayed a sensitivity of 99.1 % and specificity of100%. Safety of ultrasound findings combined with β-hCG serum quantification displayed a Positive Predictive Value of 100 % and Negative Predictive Value of 80 %.Conclusions:
The ultrasonographic diagnostic test combined with the β-hCG serum quantification has better validity and safety than the ultrasonographic test alone.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Gravidez Ectópica
Tipo de estudo:
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Idioma:
Es
Revista:
Rev. méd. (La Paz)
Assunto da revista:
MEDICINA
Ano de publicação:
2020
Tipo de documento:
Article
País de afiliação:
Bolívia
País de publicação:
Bolívia