Your browser doesn't support javascript.
loading
Biometric error analysis after cataract surgery performed by residents, in patients with high myopia with SRK/T formula and Wang-Koch formula adjustment / Análise de erros biométricos após cirurgia de catarata realizada por residentes em pacientes com alta miopia com a fórmula SRK/T com ajuste pela fórmula Wang-Koch
Beckencamp, André; Moscovici, Bernardo Kaplan; Gama, Daniel Diniz da; Bastos, Mirla Fernanda Lacerda; Santos, Françuilner Santiago dos; Correa, Vinicius Cidral; Rodrigues, Pablo Felipe; Capelanes, Nelson Chammas; Regatieri, Caio.
Afiliação
  • Beckencamp, André; Universidade Federal de São Paulo. Escola Paulista de Medicina. Department of Ophthalmology and Visual Sciences. São Paulo. BR
  • Moscovici, Bernardo Kaplan; Universidade Federal de São Paulo. Escola Paulista de Medicina. Department of Ophthalmology and Visual Sciences. São Paulo. BR
  • Gama, Daniel Diniz da; Universidade Federal de São Paulo. Escola Paulista de Medicina. Department of Ophthalmology and Visual Sciences. São Paulo. BR
  • Bastos, Mirla Fernanda Lacerda; Unidade Paulista de Oftalmologia. São Paulo. BR
  • Santos, Françuilner Santiago dos; Unidade Paulista de Oftalmologia. São Paulo. BR
  • Correa, Vinicius Cidral; Unidade Paulista de Oftalmologia. São Paulo. BR
  • Rodrigues, Pablo Felipe; Universidade Federal de São Paulo. Escola Paulista de Medicina. Department of Ophthalmology and Visual Sciences. São Paulo. BR
  • Capelanes, Nelson Chammas; Universidade Federal de São Paulo. Escola Paulista de Medicina. Department of Ophthalmology and Visual Sciences. São Paulo. BR
  • Regatieri, Caio; Universidade Federal de São Paulo. Escola Paulista de Medicina. Department of Ophthalmology and Visual Sciences. São Paulo. BR
Rev. bras. oftalmol ; 83: e0043, 2024. tab
Article em En | LILACS-Express | LILACS | ID: biblio-1569743
Biblioteca responsável: BR1.1
ABSTRACT
ABSTRACT Objective To evaluate intraocular lens power calculation and postoperative refractive errors in patients with high myopia undergoing cataract surgery, comparing predicted target refraction and actual postoperative refraction measured 30 days after surgery with SRK/T formula. Methods This retrospective analysis comprised 39 eyes of 31 patients undergoing cataract surgery through phacoemulsification with in-the-bag IOL implantation. Axial length was measured by partial coherence interferometry or immersion ultrasound biometry, with measurements greater than 26 mm and preoperative myopia greater than -6.0 D Manifest refraction was performed at the 1-month postoperative visit, and the spherical equivalent was analyzed. Results After analysis of 39 eyes of 31 patients undergoing cataract surgery with a mean axial length of 30.4 (standard deviation of 2.2) mm, the mean preoperative refractive spherical equivalent was -15.6 (standard deviation of 7.6) D, ranging from -24.0 to -13.4 D. At 30 days postoperatively, the mean spherical equivalent was -0.35 (standard deviation of 1.1) D, ranging from -2.4 to 2.50 D. Conclusion We encountered a correlation between the absolute refractive error and the dioptric power of the intraocular lens. Against expectations, in our study, ultrasound biometry yielded better results than the optical biometer device, probably due to the small number of patients undergoing optical biometry, suggesting that well-performed immersion biometry can still produce satisfactory results.
RESUMO
RESUMO Objetivo Avaliar os cálculos de potência da lente intraocular e os erros refrativos pós-operatórios em pacientes com alta miopia submetidos à cirurgia de catarata, comparando a refração-alvo prevista e a refração pós-operatória real medida 30 dias após a cirurgia com a fórmula SRK/T. Métodos Esta análise retrospectiva incluiu 39 olhos de 31 pacientes com cirurgia de catarata de facoemulsificação não complicada com implantação de lente intraocular na bolsa. Os comprimentos axiais foram medidos por biometria de coerência óptica ou ultrassônica (imersão), com medidas de axial length (AL) maiores que 26 mm em pacientes com miopia maior que -6.0 D. A refração manifesta foi realizada na consulta pós-operatória de 1 mês, e o equivalente esférico foi analisado. Resultados Após análise de 39 olhos de 31 pacientes submetidos à cirurgia de catarata com AL médio de 30,4 (desvio-padrão de 2,2) mm, o equivalente esférico refrativo médio pré-operatório foi de -15,6 (desvio-padrão de 7,6) D, variando de -24,0 a -13,4 D. Aos 30 dias de pós-operatório, o equivalente esférico médio foi de -0,35 (desvio-padrão de 1,1) D, variando de -2,4 a 2,50 D. Conclusão Encontramos uma correlação entre o erro refrativo absoluto e o poder dióptrico da lente intraocular. Contrariando as expectativas, em nosso estudo, a biometria ultrassônica apresentou melhores resultados que o biômetro óptico, provavelmente devido ao pequeno número de pacientes submetidos à biometria óptica, sugerindo que a biometria de imersão bem executada ainda pode produzir resultados satisfatórios.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Idioma: En Revista: Rev. bras. oftalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Idioma: En Revista: Rev. bras. oftalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil