Your browser doesn't support javascript.
loading
Methodological approaches to planar and volumetric scintigraphic imaging of small volume targets with high spatial resolution and sensitivity
Mejia, J; Galvis-Alonso, O. Y; Braga, J; Corrêa, R; Leite, J. P; Simões, M. V.
Afiliação
  • Mejia, J; Faculdade de Medicina de São José do Rio Preto. Departamento de Biologia Molecular. São José do Rio Preto. BR
  • Galvis-Alonso, O. Y; Faculdade de Medicina de São José do Rio Preto. Departamento de Biologia Molecular. São José do Rio Preto. BR
  • Braga, J; Instituto Nacional de Pesquisas Espaciais. Divisão de Astrofísica. São José dos Campos. BR
  • Corrêa, R; Instituto Nacional de Pesquisas Espaciais. Divisão de Ciência Espacial e Atmosférica. São José dos Campos. BR
  • Leite, J. P; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Departamento de Neurologia, Psiquiatria e Psicologia Médica. Ribeirão Preto. BR
  • Simões, M. V; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Departamento de Clínica Médica. Ribeirão Preto. BR
Braz. j. med. biol. res ; 42(8): 692-699, Aug. 2009. ilus
Article em En | LILACS | ID: lil-520790
Biblioteca responsável: BR1.1
ABSTRACT
Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target’s radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Tomografia Computadorizada de Emissão de Fóton Único / Desenho Assistido por Computador / Imageamento Tridimensional / Modelos Biológicos Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Braz. j. med. biol. res Assunto da revista: BIOLOGIA / MEDICINA Ano de publicação: 2009 Tipo de documento: Article / Project document País de afiliação: Brasil País de publicação: Brasil
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Tomografia Computadorizada de Emissão de Fóton Único / Desenho Assistido por Computador / Imageamento Tridimensional / Modelos Biológicos Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Braz. j. med. biol. res Assunto da revista: BIOLOGIA / MEDICINA Ano de publicação: 2009 Tipo de documento: Article / Project document País de afiliação: Brasil País de publicação: Brasil