Your browser doesn't support javascript.
loading
Resistencia a la Compresión de Carillas Cerámicas de Disilicato de Litio Cementadas con Cemento Resinoso Dual y Cemento Resinoso Dual Autoadhesivo en Premolares Maxilares / Compressive Resistance of Lithium Disilicate Porcelain Laminate Veneers Cemented with Dual Resin Cement and Self-adhesive Dual Resin Cement in Upper Premolars
Mellado Alfaro, Brando; Anchelia Ramirez, Shilla; Quea Cahuana, Eduardo.
Afiliação
  • Mellado Alfaro, Brando; Universidad de San Martín de Porres. Facultad de Odontología. Lima. PE
  • Anchelia Ramirez, Shilla; Universidad de San Martín de Porres. Facultad de Odontología. Lima. PE
  • Quea Cahuana, Eduardo; Universidad de San Martín de Porres. Facultad de Odontología. Lima. PE
Int. j. odontostomatol. (Print) ; 9(1): 85-89, Apr. 2015. ilus
Article em Es | LILACS | ID: lil-747482
Biblioteca responsável: CL1.1
RESUMEN
El objetivo de este trabajo fue determinar el grado de resistencia a la fuerza de compresión de las carillas de cerámica de disilicato de litio cementadas con dos agentes de resina dual en premolares maxilares. En este estudio experimental in vitro se seleccionaron 30 premolares maxilares, los cuales fueron divididos aleatoriamente en dos grupos de 15 dientes cada uno; posteriormente los especímenes fueron preparados para recibir carillas de cerámica de 0,5 mm de grosor. Las carillas de grupo 1 se cementaron con un cemento resinoso dual (CRD) y las del grupo 2 con un cemento de resina dual autoadhesivo (CRDA). Luego de cementadas fueron puestas a prueba en una máquina de ensayo universal hasta su fractura por fuerzas de compresión (N) a una velocidad de 1 mm/min. Para la comparación de medias se utilizó la prueba t de Student (a= 0,05). Los resultados mostraron diferencias estadísticamente significativas (p<0,05) entre los grupos estudiados. La media de la resistencia a la compresión de las muestras cementadas con cemento resinoso dual y cemento resinoso dual autoadhesivo fue de 677,47 N y 5500 N, respectivamente. Se determinó que las carillas de cerámica de disilicato de litio cementadas con CRD tienen mayor resistencia a la fuerza de compresión respecto a las cementadas con CRDA.
ABSTRACT
The aim of this work was to establish the resistance degree to the compression force in porcelain laminate. In this experimental in vitro study 30 premolars were selected and randomly divided in groups of 15 teeth each, subsequently specimens were prepared for ceramic veneers 0.5 mm thick. The first group was cemented with dual resin cement (CRD) and the second with dual adhesive resin cement (CRDA). After cementation was tested in a universal test machine until fracture compression forces occurred (N) at 1 mm / min speed. Student´s t-test (a= 0.05) was used to compare means. The results showed statistically significant differences (p<0.05) between groups. The mean compressive strength for cemented samples was 677.47 N and 550.0 N for dual resin cement and auto-adhesive dual resin cement respectively. It was found that porcelain laminate veneers made of lithium disilicate and cemented with CRD have greater resistance to compression force compered to CRDA.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Dente Pré-Molar / Arcada Osseodentária Tipo de estudo: Clinical_trials Limite: Humans Idioma: Es Revista: Int. j. odontostomatol. (Print) Assunto da revista: ODONTOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Peru País de publicação: Chile

Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Dente Pré-Molar / Arcada Osseodentária Tipo de estudo: Clinical_trials Limite: Humans Idioma: Es Revista: Int. j. odontostomatol. (Print) Assunto da revista: ODONTOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Peru País de publicação: Chile