Your browser doesn't support javascript.
loading
High-Dimensional Feature Selection for Automatic Classification of Coronary Stenosis Using an Evolutionary Algorithm.
Gil-Rios, Miguel-Angel; Cruz-Aceves, Ivan; Hernandez-Aguirre, Arturo; Moya-Albor, Ernesto; Brieva, Jorge; Hernandez-Gonzalez, Martha-Alicia; Solorio-Meza, Sergio-Eduardo.
Afiliação
  • Gil-Rios MA; Tecnologías de Información, Universidad Tecnológica de León, Blvd. Universidad Tecnológica 225, Col. San Carlos, León 37670, Mexico.
  • Cruz-Aceves I; CONACYT, Centro de Investigación en Matemáticas (CIMAT), A.C., Jalisco S/N, Col. Valenciana, Guanajuato 36000, Mexico.
  • Hernandez-Aguirre A; Departamento de Computación, Centro de Investigación en Matemáticas (CIMAT), A.C., Jalisco S/N, Col. Valenciana, Guanajuato 36000, Mexico.
  • Moya-Albor E; Facultad de Ingeniería, Universidad Panamericana, Augusto Rodin 498, Ciudad de México 03920, Mexico.
  • Brieva J; Facultad de Ingeniería, Universidad Panamericana, Augusto Rodin 498, Ciudad de México 03920, Mexico.
  • Hernandez-Gonzalez MA; Unidad Médica de Alta Especialidad (UMAE), Hospital de Especialidades No. 1. Centro Médico Nacional del Bajio, IMSS, Blvd. Adolfo López Mateos esquina Paseo de los Insurgentes S/N, Col. Los Paraisos, León 37320, Mexico.
  • Solorio-Meza SE; División Ciencias de la Salud, Universidad Tecnológica de México, Campus León, Blvd. Juan Alonso de Torres 1041, Col. San José del Consuelo, León 37200, Mexico.
Diagnostics (Basel) ; 14(3)2024 Jan 26.
Article em En | MEDLINE | ID: mdl-38337787
ABSTRACT
In this paper, a novel strategy to perform high-dimensional feature selection using an evolutionary algorithm for the automatic classification of coronary stenosis is introduced. The method involves a feature extraction stage to form a bank of 473 features considering different types such as intensity, texture and shape. The feature selection task is carried out on a high-dimensional feature bank, where the search space is denoted by O(2n) and n=473. The proposed evolutionary search strategy was compared in terms of the Jaccard coefficient and accuracy classification with different state-of-the-art methods. The highest feature selection rate, along with the best classification performance, was obtained with a subset of four features, representing a 99% discrimination rate. In the last stage, the feature subset was used as input to train a support vector machine using an independent testing set. The classification of coronary stenosis cases involves a binary classification type by considering positive and negative classes. The highest classification performance was obtained with the four-feature subset in terms of accuracy (0.86) and Jaccard coefficient (0.75) metrics. In addition, a second dataset containing 2788 instances was formed from a public image database, obtaining an accuracy of 0.89 and a Jaccard Coefficient of 0.80. Finally, based on the performance achieved with the four-feature subset, they can be suitable for use in a clinical decision support system.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Diagnostics (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: México País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Diagnostics (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: México País de publicação: Suíça