Point-of-Care Electrochemical Immunosensor Applied against Nosocomial Infection: Staphylococcus aureus Detection in Human Hand Skin.
de Godoy, Henri Alves; Faria, Aline Macedo; Roza, Noemí Angelica Vieira; Bach-Toledo, Larissa; Simabuco, Fernando Moreira; Scharlack, Nayara Kastem; de Oliveira, Rodrigo Bueno; Antunes, Adriane Elisabete Costa; Arthur, Rangel; Mazon, Talita.
Afiliação
  • de Godoy HA; School of Technology, State University of Campinas (UNICAMP), 13484-332 Limeira, SP, Brazil.
  • Faria AM; Centro de Tecnologia da Informação Renato Archer, CTI, 13069-901 Campinas, SP, Brazil.
  • Roza NAV; Centro de Tecnologia da Informação Renato Archer, CTI, 13069-901 Campinas, SP, Brazil.
  • Bach-Toledo L; Centro de Tecnologia da Informação Renato Archer, CTI, 13069-901 Campinas, SP, Brazil.
  • Simabuco FM; School of Applied Sciences, State University of Campinas (UNICAMP), 13484-350 Limeira, SP, Brazil.
  • Scharlack NK; School of Applied Sciences, State University of Campinas (UNICAMP), 13484-350 Limeira, SP, Brazil.
  • de Oliveira RB; School of Medical Sciences, State University of Campinas (UNICAMP), 13083-887 Campinas, SP, Brazil.
  • Antunes AEC; School of Applied Sciences, State University of Campinas (UNICAMP), 13484-350 Limeira, SP, Brazil.
  • Arthur R; School of Technology, State University of Campinas (UNICAMP), 13484-332 Limeira, SP, Brazil.
  • Mazon T; Centro de Tecnologia da Informação Renato Archer, CTI, 13069-901 Campinas, SP, Brazil.
ACS Infect Dis ; 10(6): 1949-1957, 2024 Jun 14.
Article em En | MEDLINE | ID: mdl-38741263
ABSTRACT
Staphylococcus aureus is an important pathogen that causes nosocomial infections, resulting in unacceptable morbidity and mortality rates. In this work, we proposed the construction of a nanostructured ZnO-based electrochemical immunosensor for qualitative and semiquantitative detection of S. aureus using simple methods for growing zinc oxide nanorods (ZnO NRs) on a sensor board and immobilizing the anti-S. aureus antibody on ZnO NRs through cystamine and glutaraldehyde. The immunosensor detected S. aureus in the 103-107 colony-forming unit (CFU) mL-1 range and showed a limit of detection (LoD) around 0.792 × 103 CFU mL-1. Beyond a satisfactory LoD, the developed immunosensor presented other advantages, such as high versatility for point-of-care assays and a suitable selective factor that admits the detection of the S. aureus concentration range in human hand skin after washing. Moreover, the immunosensor showed the potential to be an excellent device to control nosocomial infection by detecting the presence of S. aureus in human hand skin.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pele / Staphylococcus aureus / Óxido de Zinco / Técnicas Biossensoriais / Infecção Hospitalar / Sistemas Automatizados de Assistência Junto ao Leito / Técnicas Eletroquímicas Limite: Humans Idioma: En Revista: ACS Infect Dis Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pele / Staphylococcus aureus / Óxido de Zinco / Técnicas Biossensoriais / Infecção Hospitalar / Sistemas Automatizados de Assistência Junto ao Leito / Técnicas Eletroquímicas Limite: Humans Idioma: En Revista: ACS Infect Dis Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos