Dental implant and abutment in PEEK: stress assessment in single crown retainers on anterior region.
de Almeida, Marcus Vinicius Rocha; Ribeiro, Michele Costa Oliveira; Dos Reis-Neta, Gilda Rocha; Vargas-Moreno, Vanessa Felipe; Gomes, Rafael Soares; da Silva, Wander José; Del Bel Cury, Altair Antoninha; Marcello-Machado, Raissa Micaella.
Afiliação
  • de Almeida MVR; Departamento de prótese e periodontia, Faculdade de odontologia de Piracicaba, Universidade de Campinas - (FOP-UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo, Brasil.
  • Ribeiro MCO; Departamento de prótese e periodontia, Faculdade de odontologia de Piracicaba, Universidade de Campinas - (FOP-UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo, Brasil.
  • Dos Reis-Neta GR; Departamento de prótese e periodontia, Faculdade de odontologia de Piracicaba, Universidade de Campinas - (FOP-UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo, Brasil.
  • Vargas-Moreno VF; Departamento de prótese e periodontia, Faculdade de odontologia de Piracicaba, Universidade de Campinas - (FOP-UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo, Brasil.
  • Gomes RS; Departamento de prótese, Faculdade de tecnologia e ciência (UniFTC), Av. Luís Viana Filho, 8812 - Paralela, Salvador, BA, Brasil.
  • da Silva WJ; Departamento de prótese e periodontia, Faculdade de odontologia de Piracicaba, Universidade de Campinas - (FOP-UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo, Brasil.
  • Del Bel Cury AA; Departamento de prótese e periodontia, Faculdade de odontologia de Piracicaba, Universidade de Campinas - (FOP-UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo, Brasil.
  • Marcello-Machado RM; Departamento de prótese e periodontia, Faculdade de odontologia de Piracicaba, Universidade de Campinas - (FOP-UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo, Brasil. raissammm@gmail.com.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Article em En | MEDLINE | ID: mdl-38795258
ABSTRACT

OBJECTIVE:

Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND

METHODS:

Five 3D models were created, varying implant/abutment manufacturing materials titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone.

RESULTS:

The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups.

CONCLUSION:

Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Polímeros / Titânio / Zircônio / Benzofenonas / Teste de Materiais / Dente Suporte / Análise de Elementos Finitos / Coroas / Análise do Estresse Dentário Limite: Humans Idioma: En Revista: Clin Oral Investig Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Polímeros / Titânio / Zircônio / Benzofenonas / Teste de Materiais / Dente Suporte / Análise de Elementos Finitos / Coroas / Análise do Estresse Dentário Limite: Humans Idioma: En Revista: Clin Oral Investig Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha