Your browser doesn't support javascript.
loading
Robotic-Assisted Endovascular Treatment for Transplant Renal Artery Stenosis: A Feasibility Study.
Schmid, Bruno Pagnin; Wolosker, Nelson; Cunha, Marcela Juliano Silva; Valle, Leonardo Guedes Moreira; Galastri, Francisco Leonardo; Affonso, Breno Boueri; Nasser, Felipe.
Afiliação
  • Schmid BP; Department of Interventional Radiology, Hospital Israelita Albert Einstein Avenue, Albert Einstein Avenue, 627, Sao Paulo, SP, 05652-900, Brazil. brunopschmid@gmail.com.
  • Wolosker N; Department of Vascular and Endovascular Surgery, Hospital Israelita Albert Einstein, Sao Paulo, SP, Brazil.
  • Cunha MJS; Department of Interventional Radiology, Hospital Israelita Albert Einstein Avenue, Albert Einstein Avenue, 627, Sao Paulo, SP, 05652-900, Brazil.
  • Valle LGM; Department of Interventional Radiology, Hospital Israelita Albert Einstein Avenue, Albert Einstein Avenue, 627, Sao Paulo, SP, 05652-900, Brazil.
  • Galastri FL; Department of Interventional Radiology, Hospital Israelita Albert Einstein Avenue, Albert Einstein Avenue, 627, Sao Paulo, SP, 05652-900, Brazil.
  • Affonso BB; Department of Interventional Radiology, Hospital Israelita Albert Einstein Avenue, Albert Einstein Avenue, 627, Sao Paulo, SP, 05652-900, Brazil.
  • Nasser F; Department of Interventional Radiology, Hospital Israelita Albert Einstein Avenue, Albert Einstein Avenue, 627, Sao Paulo, SP, 05652-900, Brazil.
Cardiovasc Intervent Radiol ; 47(8): 1127-1133, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38890185
ABSTRACT

PURPOSE:

To describe a single-center experience with robotic-assisted endovascular treatment for transplant renal artery stenosis. MATERIALS AND

METHODS:

This is a single-center, retrospective, feasibility study of 4 consecutive cases of robotic-assisted endovascular surgery for transplant renal artery stenosis from October 2021 to August 2022.

RESULTS:

All lesions were identified, and stenting was performed with no complications. Conversion to manual control was not necessary. The mean fluoroscopy time was 25.25 min (range 12-60.9). A control Doppler ultrasound was routinely performed, demonstrating no residual lesions in all cases. There was no reintervention during the follow-up period. The operator learning curve was felt to be acceptable.

CONCLUSION:

Robotic-assisted endovascular treatment is a feasible technique for transplant renal artery stenosis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Obstrução da Artéria Renal / Estudos de Viabilidade / Transplante de Rim / Procedimentos Endovasculares / Procedimentos Cirúrgicos Robóticos Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Cardiovasc Intervent Radiol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Obstrução da Artéria Renal / Estudos de Viabilidade / Transplante de Rim / Procedimentos Endovasculares / Procedimentos Cirúrgicos Robóticos Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Cardiovasc Intervent Radiol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos