Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Braz J Med Biol Res ; 49(10): e5294, 2016 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-27580004

RESUMO

Determination of left ventricular ejection fraction (LVEF) using in vivo imaging is the cardiac functional parameter most frequently employed in preclinical research. However, there is considerable conflict regarding the effects of anesthetic agents on LVEF. This study aimed at assessing the effects of various anesthetic agents on LVEF in hamsters using transthoracic echocardiography. Twelve female hamsters were submitted to echocardiography imaging separated by 1-week intervals under the following conditions: 1) conscious animals, 2) animals anesthetized with isoflurane (inhaled ISO, 3 L/min), 3) animals anesthetized with thiopental (TP, 50 mg/kg, intraperitoneal), and 4) animals anesthetized with 100 mg/kg ketamine plus 10 mg/kg xylazine injected intramuscularly (K/X). LVEF obtained under the effect of anesthetics (ISO=62.2±3.1%, TP=66.2±2.7% and K/X=75.8±1.6%) was significantly lower than that obtained in conscious animals (87.5±1.7%, P<0.0001). The K/X combination elicited significantly higher LVEF values compared to ISO (P<0.001) and TP (P<0.05). K/X was associated with a lower dispersion of individual LVEF values compared to the other anesthetics. Under K/X, the left ventricular end diastolic diameter (LVdD) was increased (0.60±0.01 cm) compared to conscious animals (0.41±0.02 cm), ISO (0.51±0.02 cm), and TP (0.55±0.01 cm), P<0.0001. The heart rate observed with K/X was significantly lower than in the remaining conditions. These results indicate that the K/X combination may be the best anesthetic option for the in vivo assessment of cardiac systolic function in hamsters, being associated with a lower LVEF reduction compared to the other agents and showing values closer to those of conscious animals with a lower dispersion of results.


Assuntos
Anestésicos/farmacologia , Volume Sistólico/efeitos dos fármacos , Função Ventricular Esquerda/efeitos dos fármacos , Animais , Combinação de Medicamentos , Ecocardiografia/métodos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/efeitos dos fármacos , Isoflurano/farmacologia , Ketamina/farmacologia , Mesocricetus , Valores de Referência , Sístole/efeitos dos fármacos , Tiopental/farmacologia , Fatores de Tempo , Xilazina/farmacologia
2.
Braz. j. med. biol. res ; 43(12): 1160-1166, Dec. 2010. ilus
Artigo em Inglês | LILACS | ID: lil-569007

RESUMO

The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.


Assuntos
Animais , Masculino , Ratos , Câmaras gama/veterinária , Coração , Rim , Modelos Animais , Tomografia Computadorizada de Emissão de Fóton Único/veterinária , Algoritmos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Ratos Wistar , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos
3.
Braz J Med Biol Res ; 43(12): 1160-6, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21085887

RESUMO

The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target's three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.


Assuntos
Câmaras gama/veterinária , Coração/diagnóstico por imagem , Rim/diagnóstico por imagem , Modelos Animais , Tomografia Computadorizada de Emissão de Fóton Único/veterinária , Algoritmos , Animais , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Imagens de Fantasmas , Ratos , Ratos Wistar , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
Braz J Med Biol Res ; 42(8): 692-9, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19649396

RESUMO

Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target's radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.


Assuntos
Desenho Assistido por Computador , Imageamento Tridimensional/veterinária , Modelos Biológicos , Tomografia Computadorizada de Emissão de Fóton Único/veterinária , Animais , Aumento da Imagem , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos
5.
Braz. j. med. biol. res ; 42(8): 692-699, Aug. 2009. ilus
Artigo em Inglês | LILACS | ID: lil-520790

RESUMO

Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target’s radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.


Assuntos
Animais , Desenho Assistido por Computador , Imageamento Tridimensional/veterinária , Modelos Biológicos , Tomografia Computadorizada de Emissão de Fóton Único/veterinária , Aumento da Imagem , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos
6.
Braz J Med Biol Res ; 39(1): 1-7, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16400459

RESUMO

The present study describes an auxiliary tool in the diagnosis of left ventricular (LV) segmental wall motion (WM) abnormalities based on color-coded echocardiographic WM images. An artificial neural network (ANN) was developed and validated for grading LV segmental WM using data from color kinesis (CK) images, a technique developed to display the timing and magnitude of global and regional WM in real time. We evaluated 21 normal subjects and 20 patients with LVWM abnormalities revealed by two-dimensional echocardiography. CK images were obtained in two sets of viewing planes. A method was developed to analyze CK images, providing quantitation of fractional area change in each of the 16 LV segments. Two experienced observers analyzed LVWM from two-dimensional images and scored them as: 1) normal, 2) mild hypokinesia, 3) moderate hypokinesia, 4) severe hypokinesia, 5) akinesia, and 6) dyskinesia. Based on expert analysis of 10 normal subjects and 10 patients, we trained a multilayer perceptron ANN using a back-propagation algorithm to provide automated grading of LVWM, and this ANN was then tested in the remaining subjects. Excellent concordance between expert and ANN analysis was shown by ROC curve analysis, with measured area under the curve of 0.975. An excellent correlation was also obtained for global LV segmental WM index by expert and ANN analysis (R2 = 0.99). In conclusion, ANN showed high accuracy for automated semi-quantitative grading of WM based on CK images. This technique can be an important aid, improving diagnostic accuracy and reducing inter-observer variability in scoring segmental LVWM.


Assuntos
Ecocardiografia/métodos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Curva ROC , Índice de Gravidade de Doença
7.
Braz. j. med. biol. res ; 39(1): 1-7, Jan. 2006. ilus
Artigo em Inglês | LILACS | ID: lil-419153

RESUMO

The present study describes an auxiliary tool in the diagnosis of left ventricular (LV) segmental wall motion (WM) abnormalities based on color-coded echocardiographic WM images. An artificial neural network (ANN) was developed and validated for grading LV segmental WM using data from color kinesis (CK) images, a technique developed to display the timing and magnitude of global and regional WM in real time. We evaluated 21 normal subjects and 20 patients with LVWM abnormalities revealed by two-dimensional echocardiography. CK images were obtained in two sets of viewing planes. A method was developed to analyze CK images, providing quantitation of fractional area change in each of the 16 LV segments. Two experienced observers analyzed LVWM from two-dimensional images and scored them as: 1) normal, 2) mild hypokinesia, 3) moderate hypokinesia, 4) severe hypokinesia, 5) akinesia, and 6) dyskinesia. Based on expert analysis of 10 normal subjects and 10 patients, we trained a multilayer perceptron ANN using a back-propagation algorithm to provide automated grading of LVWM, and this ANN was then tested in the remaining subjects. Excellent concordance between expert and ANN analysis was shown by ROC curve analysis, with measured area under the curve of 0.975. An excellent correlation was also obtained for global LV segmental WM index by expert and ANN analysis (R² = 0.99). In conclusion, ANN showed high accuracy for automated semi-quantitative grading of WM based on CK images. This technique can be an important aid, improving diagnostic accuracy and reducing inter-observer variability in scoring segmental LVWM.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Ecocardiografia/métodos , Hipertrofia Ventricular Esquerda , Interpretação de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Disfunção Ventricular Esquerda , Estudos de Casos e Controles , Modelos Lineares , Curva ROC , Índice de Gravidade de Doença
8.
Thromb Res ; 100(4): 263-9, 2000 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-11113269

RESUMO

We investigated two genetic polymorphisms in the tumor necrosis factor locus (TNF-alpha -308 G-->A and LT-alpha +252 A-->G) as risk factors for coronary atherothrombotic disease (CAD) by determining its prevalence in 148 survivors of myocardial infarction (MI) with angiographically-proven severe CAD, and in 148 age-, gender- and race-matched controls. The odds ratio (OR) for MI related to the mutant TNF-alpha and LT-alpha alleles was 0.8 (CI95: 0.4-1.3) and 1. 3 (CI95: 0.8-2.0), respectively. We also sought interaction of smoking and metabolic risk factors for MI with each mutant genotype. Smokers not carrying the LT-alpha +252 A-->G mutation had a risk of MI of 2.7 (CI95: 1.4-5.4) whereas in smoking carriers the risk was 6. 9 (CI95: 3.4-14.1). An interactive effect of the LT-alpha mutation may also exist with dyslipidemia (OR for MI in non-carriers was 12 [CI95: 3.2-41.3] and in carriers the OR was 39, [CI95: 5.1-301] and with obesity (OR for MI was 2.7, [CI95: 1-7.2] in non-carriers and in carriers the OR was 6 [CI95: 2.1-16.8]). Lastly, the OR for MI in obese non-carriers of TNF-alpha -308 G-->A was 2.8 (CI95: 1.3-6) and in obese carriers the OR was 14.5 (CI95: 1.8-113). Although significant interactive effects could not be detected, the findings suggest that interaction of polymorphisms in the TNF locus with major risk factors for CAD may exist, and should be explored in larger studies.


Assuntos
Infarto do Miocárdio/etiologia , Fator de Necrose Tumoral alfa/genética , Adulto , Estudos de Casos e Controles , Feminino , Frequência do Gene , Genótipo , Heterozigoto , Humanos , Hiperlipidemias/genética , Linfotoxina-alfa/efeitos adversos , Linfotoxina-alfa/genética , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/genética , Infarto do Miocárdio/metabolismo , Obesidade , Razão de Chances , Mutação Puntual , Polimorfismo Genético , Isoformas de Proteínas/genética , Fatores de Risco , Fumar/efeitos adversos , Fator de Necrose Tumoral alfa/efeitos adversos
9.
Am J Cardiol ; 86(9): 975-81, 2000 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11053710

RESUMO

Impairment of sinus node autonomic control and myocardial perfusion disturbances have been described in patients with chronic Chagas' cardiomyopathy. However, it is not clear how these conditions contribute to myocardial damage. In this investigation, iodine-123 (I-123) meta-iodobenzylguanidine (MIBG) and thallium-201 myocardium segmental uptake were studied in correlation with the severity of left ventricular (LV) dysfunction detected in various phases of Chagas' heart disease. Group I consisted of 12 subjects (43 +/- 4 years, 7 men) with no symptoms and no cardiac involvement on electrocardiogram (ECG) or echocardiography; group II consisted of 13 patients (48 +/- 3 years, 9 men) with abnormal resting ECG and/or echocardiographic segmental abnormalities, and LV ejection fraction of > or = 0.5; group III was comprised of 12 patients (59 +/- 3 years, 10 men) with more severe heart disease, LV dilation, and LV ejection fraction of < 0.5. Eighteen control volunteers (38 +/- 3 years, 9 men) were also included in the study. I-123 MIBG single-photon emission computed tomographic (SPECT) segmental uptake defects were observed in group I (33%), group II (77%), and group III (92%). Quantitative analysis showed mean areas of reduced LV I-123-MIBG uptake: group I was 3.7 +/- 2.1%; group II was 8.3 +/- 2.3%; and group III was 19.0 +/- 3.3%. The differences between group I and both groups II and III were statistically significant (p < 0.001, analysis of variance test). Myocardial perfusion defects (reversible, fixed, and paradox) were observed in group I (83%), group II (69%), and group III (83%). A marked topographic association between perfusion, innervation, and wall motion abnormalities (assessed by gated-SPECT perfusion studies) was observed in all the groups. Defects predominated in the inferior, posterior lateral, and apical LV regions. Thus, extensive impairment of cardiac sympathetic function at the ventricular level occured early in the course of Chagas' cardiomyopathy and was related to regional myocardial perfusion disturbances, before wall motion abnormalities. Both conditions are associated with progression of ventricular dysfunction.


Assuntos
Cardiomiopatia Chagásica/complicações , Cardiomiopatia Chagásica/diagnóstico por imagem , Coração/inervação , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , 3-Iodobenzilguanidina , Adulto , Análise de Variância , Cardiomiopatia Chagásica/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Probabilidade , Cintilografia , Valores de Referência , Fluxo Sanguíneo Regional , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Simpatectomia , Sistema Nervoso Simpático/fisiologia , Radioisótopos de Tálio , Disfunção Ventricular Esquerda/mortalidade
10.
Braz J Med Biol Res ; 33(3): 301-6, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10719381

RESUMO

Although iron can catalyze the production of free radicals involved in LDL lipid peroxidation, the contribution of iron overload to atherosclerosis remains controversial. The description of two mutations in the HFE gene (Cys282Tyr and His63Asp) related to hereditary hemochromatosis provides an opportunity to address the question of the association between iron overload and atherosclerosis. We investigated the prevalence of HFE mutations in 160 survivors of myocardial infarction with angiographically demonstrated severe coronary atherosclerotic disease, and in 160 age-, gender- and race-matched healthy control subjects. PCR amplification of genomic DNA followed by RsaI and BclI restriction enzyme digestion was used to determine the genotypes. The frequency of the mutant Cys282Tyr allele was identical among patients and controls (0.022; carrier frequency, 4.4%), whereas the mutant His63Asp allele had a frequency of 0.143 (carrier frequency, 27.5%) in controls and of 0.134 (carrier frequency, 24.5%) in patients. Compound heterozygotes were found in 2 of 160 (1.2%) controls and in 1 of 160 (0.6%) patients. The finding of a similar prevalence of Cys282Tyr and His63Asp mutations in the HFE gene among controls and patients with coronary atherothrombotic disease, indirectly questions the possibility of an association between hereditary hemochromatosis and atherosclerosis.


Assuntos
Doença da Artéria Coronariana/genética , Genes MHC Classe I/genética , Antígenos HLA/genética , Antígenos de Histocompatibilidade Classe I/genética , Proteínas de Membrana , Mutação , Adulto , Alelos , Feminino , Frequência do Gene , Hemocromatose/genética , Proteína da Hemocromatose , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA